Gateways with OPC UA from Bihl+Wiedemann

Using OPC UA in Bihl+Wiedemann Gateways you can release and then access your machine data as desired. The following data can be called up over your company network (examples):

  • I/O map for both ASi circuits and monitors
  • Device diagnostics
  • Fieldbus bits
  • Slave addressing
  • Safety diagnostics + Safe Link diagnostics
  • ASi EC flags and ASi fault detector
  • Safety at Work Monitor (max. 64 release circuits)

PROFINET, OPC UA

Figure Type Model

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety communication Article No.
BWU3852
PROFINET ASi-5/ASi-3
Gateway
OPC UA, PROFINET, REST API
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
no local safe inputs
no local safe output
no Safety communication
BWU3848
PROFINET ASi-5/ASi-3
Gateway
OPC UA, PROFINET, REST API
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 8 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
no local safe inputs
no local safe output
no Safety communication
BWU3847
24 Volt ASi-5/ASi-3 Gateway
Gateway
OPC UA, PROFINET, REST API
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet fieldbus
no local safe inputs
no local safe output
no Safety communication
BWU3674
PROFIsafe, PROFINET, ASi-5 / ASi-3
Gateway with integrated Safety Monitor
OPC UA, PROFINET, REST API
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
PROFIsafe (F-CPU), Safe Link
BWU3862
PROFIsafe, PROFINET, ASi-5 / ASi-3
Gateway with integrated Safety Monitor
OPC UA, PROFINET, REST API
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
PROFIsafe (F-CPU), Safe Link
BWU4000
Safety, PROFINET ASi-5/ASi-3
Gateway with integrated Safety Monitor
OPC UA, PROFINET, REST API
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
Safe Link
BWU3863
Safety, PROFINET ASi-5/ASi-3
Gateway with integrated Safety Monitor
OPC UA, PROFINET, REST API
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
Safe Link
BWU3833
PROFIsafe, PROFINET, ASi-5 / ASi-3
Gateway with integrated Safety Monitor
OPC UA, PROFINET, REST API
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
no local safe inputs
no local safe output
PROFIsafe (F-CPU), Safe Link
BWU3998
Safety, PROFINET ASi-5/ASi-3
Gateway with integrated Safety Monitor
OPC UA, PROFINET, REST API
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
no local safe inputs
no local safe output
Safe Link

 

 

EtherNet/IP + ModbusTCP, OPC UA

Figure Type Model

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety communication Article No.
BWU3851
EtherNet/IP + Modbus TCP ASi-5/ASi-3
Gateway
EtherNet/IP, Modbus/TCP, OPC UA, REST API
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
no local safe inputs
no local safe output
no Safety communication
BWU3849
24 Volt ASi-5/ASi-3 Gateway
Gateway
EtherNet/IP, Modbus/TCP, OPC UA, REST API
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet fieldbus
no local safe inputs
no local safe output
no Safety communication
BWU3857
Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3
Gateway with integrated Safety Monitor
EtherNet/IP, Modbus/TCP, OPC UA, REST API
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
CIP Safety over EtherNet/IP, Safe Link
BWU3825
Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3
Gateway with integrated Safety Monitor
EtherNet/IP, Modbus/TCP, OPC UA, REST API
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
Safe Link
BWU3866
Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3
Gateway with integrated Safety Monitor
EtherNet/IP, Modbus/TCP, OPC UA, REST API
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
Safe Link

 

 

EtherCAT, OPC UA

Figure Type Model

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety communication Article No.
BWU3854
24 Volt ASi-5/ASi-3 Gateway
Gateway
EtherCAT, OPC UA, REST API
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic
no local safe inputs
no local safe output
no Safety communication
BWU3858
Safety, EtherCAT ASi-5/ASi-3
Gateway with integrated Safety Monitor
EtherCAT, OPC UA, REST API
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
FSoE, Safe Link
BWU3991
Safety, EtherCAT ASi-5/ASi-3
Gateway with integrated Safety Monitor
EtherCAT, OPC UA, REST API
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
Safe Link

 

 

Sercos, OPC UA

Figure Type Model

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety communication Article No.
BWU3861
Safety, Sercos ASi-5/ASi-3
Gateway with integrated Safety Monitor
OPC UA, REST API, Sercos
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
Safe Link, safe Schneider drives over Sercos
BWU3860
Safety, Sercos ASi-5/ASi-3
Gateway with integrated Safety Monitor
OPC UA, REST API, Sercos
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
CIP Safety over Sercos, Safe Link
BWU3845
Safety, Sercos ASi-5/ASi-3
Gateway with integrated Safety Monitor
OPC UA, REST API, Sercos
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
no local safe inputs
no local safe output
CIP Safety over Sercos, Safe Link

 

 

BACnet/IP ASi

Figure Type Model

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety
Safety communication Article No.
BWU3356
BACnet/IP ASi
Gateway
BACnet/IP, OPC UA, REST API
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
Ethernet diagnostic, Ethernet fieldbus
no local safe output
no local safe inputs
no Safety communication
BWU4001
Safety, BACnet/IP
Gateway with integrated Safety Monitor
BACnet/IP, OPC UA, REST API
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
Ethernet diagnostic, Ethernet fieldbus
6 release circuits, 6 x electronic safe outputs
3 x 2 channels
Safe Link