Gateways with OPC UA from Bihl+Wiedemann
Using OPC UA in Bihl+Wiedemann Gateways you can release and then access your machine data as desired. The following data can be called up over your company network (examples):
- I/O map for both ASi circuits and monitors
- Device diagnostics
- Fieldbus bits
- Slave addressing
- Safety diagnostics + Safe Link diagnostics
- ASi EC flags and ASi fault detector
- Safety at Work Monitor (max. 64 release circuits)
PROFINET, OPC UA
Figure | Type | Model | Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:
| Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.
| Suitable for applications up to category 4/PLe/SIL 3. | Safety communication | Article No. |
---|---|---|---|---|---|---|---|---|---|---|
PROFINET ASi-5/ASi-3
|
Gateway
|
OPC UA, PROFINET, REST API
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
no local safe inputs
|
no local safe output
|
no Safety communication
| BWU3852 ASi-5/ASi-3 PROFINET Gateway in stainless steel, 2 ASi-5/ASi-3 masters | |
PROFINET ASi-5/ASi-3
|
Gateway
|
OPC UA, PROFINET, REST API
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 8 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
no local safe inputs
|
no local safe output
|
no Safety communication
| BWU3848 ASi-5/ASi-3 PROFINET Gateway in stainless steel, 1 ASi-5/ASi-3 master | |
24 Volt ASi-5/ASi-3 Gateway
|
Gateway
|
OPC UA, PROFINET, REST API
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus
|
no local safe inputs
|
no local safe output
|
no Safety communication
| BWU3847 24 Volt ASi-5/ASi-3 PROFINET Gateway in stainless steel, 1 ASi-5/ASi-3 master | |
PROFIsafe, PROFINET, ASi-5 / ASi-3
|
Gateway with integrated Safety Monitor
|
OPC UA, PROFINET, REST API
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
PROFIsafe (F-CPU), Safe Link
| BWU3674 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters | |
PROFIsafe, PROFINET, ASi-5 / ASi-3
|
Gateway with integrated Safety Monitor
|
OPC UA, PROFINET, REST API
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
PROFIsafe (F-CPU), Safe Link
| BWU3862 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master | |
Safety, PROFINET ASi-5/ASi-3
|
Gateway with integrated Safety Monitor
|
OPC UA, PROFINET, REST API
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| BWU4000 ASi-5/ASi-3 PROFINET Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters | |
Safety, PROFINET ASi-5/ASi-3
|
Gateway with integrated Safety Monitor
|
OPC UA, PROFINET, REST API
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| BWU3863 ASi-5/ASi-3 PROFINET Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master | |
PROFIsafe, PROFINET, ASi-5 / ASi-3
|
Gateway with integrated Safety Monitor
|
OPC UA, PROFINET, REST API
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
no local safe inputs
|
no local safe output
|
PROFIsafe (F-CPU), Safe Link
| BWU3833 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 master | |
Safety, PROFINET ASi-5/ASi-3
|
Gateway with integrated Safety Monitor
|
OPC UA, PROFINET, REST API
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
no local safe inputs
|
no local safe output
|
Safe Link
| BWU3998 ASi-5/ASi-3 PROFINET Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
EtherNet/IP + ModbusTCP, OPC UA
Figure | Type | Model | Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:
| Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.
| Suitable for applications up to category 4/PLe/SIL 3. | Safety communication | Article No. |
---|---|---|---|---|---|---|---|---|---|---|
EtherNet/IP + Modbus TCP ASi-5/ASi-3
|
Gateway
|
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
no local safe inputs
|
no local safe output
|
no Safety communication
| BWU3851 ASi-5/ASi-3 EtherNet/IP™+ModbusTCP Gateway in stainless steel, 2 ASi-5/ASi-3 masters | |
24 Volt ASi-5/ASi-3 Gateway
|
Gateway
|
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus
|
no local safe inputs
|
no local safe output
|
no Safety communication
| BWU3849 24 Volt ASi-5/ASi-3 EtherNet/IP™ + Modbus TCP Gateway in stainless steel, 1 ASi-5/ASi-3 master | |
Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3
|
Gateway with integrated Safety Monitor
|
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
CIP Safety over EtherNet/IP, Safe Link
| BWU3857 ASi-5/ASi-3 CIP Safety™ over EtherNet/IP™ + ModbusTCP Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters | |
Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3
|
Gateway with integrated Safety Monitor
|
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| BWU3825 ASi-5/ASi-3 EtherNet/IP™ + ModbusTCP Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters | |
Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3
|
Gateway with integrated Safety Monitor
|
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| BWU3866 ASi-5/ASi-3 EtherNet/IP™ + ModbusTCP Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
EtherCAT, OPC UA
Figure | Type | Model | Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:
| Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.
| Suitable for applications up to category 4/PLe/SIL 3. | Safety communication | Article No. |
---|---|---|---|---|---|---|---|---|---|---|
24 Volt ASi-5/ASi-3 Gateway
|
Gateway
|
EtherCAT, OPC UA, REST API
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic
|
no local safe inputs
|
no local safe output
|
no Safety communication
| BWU3854 24 Volt ASi-5/ASi-3 EtherCAT Gateway in stainless steel, 1 ASi-5/ASi-3 master | |
Safety, EtherCAT ASi-5/ASi-3
|
Gateway with integrated Safety Monitor
|
EtherCAT, OPC UA, REST API
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
FSoE, Safe Link
| BWU3858 ASi-5/ASi-3 Safety over EtherCAT Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters | |
Safety, EtherCAT ASi-5/ASi-3
|
Gateway with integrated Safety Monitor
|
EtherCAT, OPC UA, REST API
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| BWU3991 ASi-5/ASi-3 EtherCAT Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
Sercos, OPC UA
Figure | Type | Model | Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:
| Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.
| Suitable for applications up to category 4/PLe/SIL 3. | Safety communication | Article No. |
---|---|---|---|---|---|---|---|---|---|---|
Safety, Sercos ASi-5/ASi-3
|
Gateway with integrated Safety Monitor
|
OPC UA, REST API, Sercos
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link, safe Schneider drives over Sercos
| BWU3861 ASi-5/ASi-3 safe Schneider drives over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters | |
Safety, Sercos ASi-5/ASi-3
|
Gateway with integrated Safety Monitor
|
OPC UA, REST API, Sercos
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
CIP Safety over Sercos, Safe Link
| BWU3860 ASi-5/ASi-3 CIP Safety™ over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters | |
Safety, Sercos ASi-5/ASi-3
|
Gateway with integrated Safety Monitor
|
OPC UA, REST API, Sercos
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic
|
no local safe inputs
|
no local safe output
|
CIP Safety over Sercos, Safe Link
| BWU3845 ASi-5/ASi-3 CIP Safety™ over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
BACnet/IP ASi
Figure | Type | Model | Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:
| Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Suitable for applications up to category 4/PLe/SIL 3. | Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.
| Safety communication | Article No. |
---|---|---|---|---|---|---|---|---|---|---|
BACnet/IP ASi
|
Gateway
|
BACnet/IP, OPC UA, REST API
|
2 ASi networks, 2 ASi-3 Masters
|
no, max. 8 A/ASi network, redundant supply
|
Ethernet diagnostic, Ethernet fieldbus
|
no local safe output
|
no local safe inputs
|
no Safety communication
| BWU3356 ASi-3 BACnet/IP Gateway in stainless steel, 2 masters | |
Safety, BACnet/IP
|
Gateway with integrated Safety Monitor
|
BACnet/IP, OPC UA, REST API
|
2 ASi networks, 2 ASi-3 Masters
|
no, max. 8 A/ASi network, redundant supply
|
Ethernet diagnostic, Ethernet fieldbus
|
6 release circuits, 6 x electronic safe outputs
|
3 x 2 channels
|
Safe Link
| BWU4001 ASi-3 BACnet/IP Gateway with integrated Safety Monitor, 2 ASi masters |