ASi POWERLINK Gateways – ready für Industry 4.0 and ideal for B&R PLCs

ASi POWERLINK Gateways for standard and safety – always equipped with OPC UA and REST API

Our ASi gateways with POWERLINK interface are available with and without an integrated safety monitor. They are ideal for connecting AS-Interface (ASi) to a B&R PLC. With the state-of-the-art IT interfaces OPC UA and REST API, you can implement IIoT projects quickly and easily. As an edge device, a single gateway collects data from hundreds of sensors and actuators - and can make it available to cloud-based databases, for example.

 

All modern ASi-5/ASi-3 gateways can be securely updated in the field and can therefore meet future safety requirements long after commissioning. In addition, ASi already guarantees a high level of cyber security due to its structure. Find out more about IIoT and Industry 4.0 here.

For standard applications

ASi POWERLINK Gateways without integrated safety monitor

We recommend for almost all standard applications the article BWU4016. Here you also benefit from our new power supply generation.

 

Product selector

BWU4016

  • 1 ASi circuit, 1 ASi-5/ASi-3 Master

  • integrated decoupling
  • max. 4 A per ASi circuit

  • Diagnostics and configuration via Ethernet diagnostic interface

  • OPC UA interface and integrated webserver for easy diagnostics and maintenance

For openSafety applications

ASi POWERLINK Gateway with integrated openSafety communication

However, if you are dependent on openSafety communication – e.g. due to the use of safe B&R PLCs – you can alternatively use the ASi POWERLINK gateway BWU3865 (for 2 ASi circuits). The gateway offers integrated openSafety communication for easy integration of the safe signals into the safe B&R PLC.

BWU3865

  • 2 ASi circuits, 2 ASi-5/ASi-3 Master
  • integrated decoupling
  • max. 4 A per ASi circuit
  • Diagnostics and configuration via Ethernet diagnostic interface
  • Safety communication via Safe Link
  • OPC UA interface and integrated webserver for easy diagnostics and maintenance
  • openSafety over POWERLINK communication integrated

Special assemblies on request

If there is no suitable device for you, please contact us. Special assemblies on request are possible.

 

Request now

Do you have questions about our ASi POWERLINK Gateways?

ASi – A resource-saving technology

Thanks to the greatly reduced wiring effort with AS-Interface, you save assembly and material costs. This saves valuable resources.

 

More information!