ASi-5 - Automation reinvented.

Your path into the digital future

ASi-5 is the latest innovation stage of AS-Interface (ASi), a globally standardised fieldbus system for the first automation level. ASi connects sensors and actuators with a controller via a single two-conductor profile cable. The yellow ASi cable transmits power and data at the same time.

 

The proven main benefits of ASi are, among others, dramatically less wiring, free choice of topology and cost-efficient integration of safety on the same infrastructure. In addition, compared to other fieldbus systems, ASi needs no connectors for data and power integration.

ASi-5 - great data bandwidth, short cycle times

ASi-5 now enables you to transmit larger data volumes significantly faster. Great data bandwidth and short cycle times – comparable to Ethernet systems – allow for many new possibilities with AS-Interface. For example, ASi-5 now transmits analogue values much faster and it is easier than ever to integrate smart sensors, e.g., IO-Link sensors with up to 32 bytes.

 

Provides valuable information

More than anything, Industry 4.0 and increasing digitalization require a good data layer. As they supply additional data, smart sensors are becoming more and more important. This makes ASi-5 a key building block for your journey to the digital future, because there was one prevailing reason for evolving AS-Interface: being able to transport more and more data, without restrictions, to where they can yield valuable information. Using the integrated OPC UA servers of our ASi-5/ASi-3 gateways, you can even do this directly and in parallel with the fieldbus.

 

An affordable alternative

Another benefit of the significantly higher performance: Our new ASi-5 modules enable the cost-efficient and fast collection of numerous inputs and outputs in one place, making the modules an affordable alternative to other fieldbus solutions.

 

More about AS-Interface

Compatible with all ASi generations

ASi-5 is compatible with all earlier ASi devices and components. Therefore, you can easily use ASi-5 modules together with ASi modules of any previous generation – in existing as well as in new ASi networks because all ASi generations work in parallel on the same cable.

 

If you already use ASi there is no need to replace existing ASi modules. Simply connect additional ASi-5 modules, for example in system sections with additional demands on speed, data volume or I/O density.

 

To use ASi-5 nodes all you need is a Bihl+Wiedemann ASi-5 / ASi-3 gateway. For the ASi-5 launch, this gateway is available in two variants: for PROFINET and EtherNet/IP. Both gateways have a double master and an integrated safety monitor. The OPC UA server, which is also integrated with both variants, makes it possible to easily transmit data directly from the field level to Industry 4.0 applications.

 

Without ASi-5 module, the new ASi-5 / ASi-3 gateways work exactly as earlier Bihl+Wiedemann gateways because the ASi-3 part remains unchanged. Using our new gateways you can easily replace existing gateways.

 

By the way, compatibility has been an AS-Interface trade mark for over 20 years. This protects not just your investments but each new ASi generation also makes you more future-proof.

 

ASi-5/ASi-3 Gateways are advantageous even without ASi-5 nodes

ASi-5/ASi-3 gateways are clearly the most powerful ASi-3 gateways. It is therefore also useful if you do not (yet) use ASi-5 modules in your system. Benefit from the advantages of our new ASi-5/ASi-3 gateways:

 

  • Field update capability: Firmware and security updates are installed in a tamper-proof way; new functions are quickly available. Users decide for themselves which updates they want to install on the gateways and nodes of their choice.
  • Integrated OPC UA server: Data from the field level can be transmitted directly and easily to Industry 4.0 applications.
  • Integrated web server: among other things, it enables fast system diagnostics via remote maintenance or convenient addressing of the nodes during commissioning.
  • Cyber security: The Ethernet fieldbus and Ethernet diagnostic interface are subjected to strict load tests by means of the Achilles test software Level 1 and 2 (Version 3.18); end-to-end encryption takes place via the Bihl+Wiedemann server.

ASi-5 – Your advantages at a glance

High bandwidth

Process data size from 16 bits to 32 bytes per node

Short cycle time

up to 384 digital inputs and 384 digital outputs in just 1.27 ms

Full compatibility

Compatible with all earlier ASi devices and components

Easy integration

Intelligent sensors and actuators like IO-Link are simple to integrate

Save valuable resources

With AS-Interface, you do not need expensive plugs or sockets and only a single cable. This significantly reduces assembly times and material costs. In addition, valuable resources such as copper or plastic, which are required to manufacture the components, can be saved on a large scale. And energy consumption during cable production is greatly reduced. There is also a positive environmental effect when it comes to disposal – less waste is produced.

 

Jochen Bihl talks about ASi-5, the new innovating step in AS-Interface. He explains how users can profit from shorter cycle times and greater data bandwidth – and how easy it is to use ASi-5 and ASi-3 together.

 

Video length: 2:25

ASi-5 is a joint development of several manufacturers of ASi. Jochen Bihl and Bernhard Wiedemann, who was the technical leader of the cross-company development group, explain, how the new generation of AS-Interface was created.

 

Video length: 2:30

Benefit from all well-proven ASi strengths...

  • Transmit data and power in a single two-conductor profile cable
  • Freely choose your topology without costly switches (ring, star, line)
  • Cost-efficiently integrate safety on the same infrastructure
  • Easily install and expand your system using ASi piercing technology
  • Certified products for manufacturer-independent compatibility
  • Affordable noise-resistant system that does not require shielding

… and from the new powerful ASi-5

  • 1.27ms cycle time for up to 384 input and 384 output bits
  • 16-bit I/O data and profiles with up to 32 bytes of process data for each node
  • Easy integration of smart sensors and actuators such as IO-Link
  • ASi-5 is compatible with all earlier ASi generations for combined use of different ASi modules
  • ASi safety and ASi-5 easily work together
  • Highly economical because of reduced costs per input / output
  • Advanced diagnostics for predictive maintenance

Bihl+Wiedemann’s ASi-5 products

 

ASi-5/ASi-3 Gateways

Here you can find the currently available variants of our ASi-5/ASi-3 gateways. We will gradually develop additional gateways – even for other field buses.

ASi-5/ASi-3 Gateways with Safety Monitor

  • Compatible with existing networks

  • 1.27 ms cycle time for up to 384 input and 384 output bits
  • Most powerful platform by Bihl+Wiedemann
  • ASi Safety integrated
    • Safety, PROFINET
    • Safety, EtherNet/IP + Modbus TCP
    • Safety, EtherCAT
  • Safe fieldbus protocol
    • CIP Safety via EtherNet/IP
    • PROFIsafe via PROFINET
    • Safety over EtherCAT
    • CIP Safety via Sercos


Product selector

ASi-5/ASi-3 Gateways in Stainless Steel

  • Compatible with existing networks
  • 1.27 ms cycle time for up to 384 input and 384 output bits
  • Cost-effective solution for all standard applications from Bihl+Wiedemann
  • Field bus systems, e. g.:
    • PROFINET
    • EtherNet/IP + Modbus TCP
    • EtherCAT
    • POWERLINK


Product selector

Compatible with all common fieldbuses

  • PROFINET
  • EtherNet/IP + ModbusTCP
  • EtherCAT
  • POWERLINK
  • Sercos

 

Safe fieldbus protocols are supported

  • PROFIsafe
  • CIP Safety
  • Safety over EtherCAT

 

ASi-5 nodes

Here you can find the currently available ASi-5 nodes. We will continuously develop additional product variants.

ASi-5 digital modules

  • High I/O density
  • Low overhead costs
  • 16I
  • 8I/8O
  • 8I


Product selector

ASi-5 selfconfiguring I/O modules

  • 16 digital inputs/outputs with ASi-5 in 1,27 ms
  • Selfconfiguring
  • Detailed channel-specific diagnostics
  • State of the outputs can be read back individually
  • High I/O density
  • Low overhead costs
  • Inexpensive digital outputs


Product selector

ASi-5 modules with integrated IO-Link master

  • Simple parametrization via ASi Control Tools360 / ASIMON360
  • 4 × 16 Bit user data up to 1,27 ms available
  • 2 × class A, 2 × class B
  • 4 × class A
  • 4 x IO-Link port, IP20
  • 1 × class A, 1 × Class B
  • 1 × class B


Product selector

ASi-5 Safety input modules

  • Convenient parameterization via ASIMON360
  • For floating contacts or for OSSDs or a combination
  • 2 × 2-channel safe inputs
  • Up to 12 standard I/Os
  • Special solutions for Muting applications
  • Only 1 ASi-5 address


Product selector

ASi-5 motor modules

  • Input power provided by ASi

  • Motors supplied from AUX

  • Cyclic writing of speed and ramps possible

  • Flat design, installation in cable duct possible

  • Control of up to 4 × 48 V motorized rollers per module (e.g. Interroll)

  • Control of up to 4 × 24 V motorized rollers per module (e.g. Interroll, Itho Denki)

  • Drive solutions with Serial Interface (e.g. SEW, Lenze, NORD, EBM-Papst, Rockwell, Bonfiglioli)
     

Product selector

ASi-5 counter modules

  • Simple parametrization
  • Configurable via Bihl+Wiedemann Software-Suites
  • Up to 4 × 16-bit counter values available in 1.27 ms
  • Counter frequency up to 250 kHz
  • Up to 4 × 2-channels inputs


Product selector

ASi-5 application reports from the field

ASi-5 reduces machine costs, paves the way for IIoT, is ideal for demanding drive technology applications and introduces you to many new options thanks to its high data bandwidth and short cycle times. Here you can read a few of the many success stories involving the resource-saving bus system with the simplest connection technology.

 

Read Application Reports now!

The latest gateways, cost-saving input modules, and the first configurable I/O module with 2 safe outputs are available

ASi-5 Safety is certified and ready for use and complements optimally the established ASi Safety. The latest Safety generation can be easily integrated into existing solutions. Main advantage of ASi-5 Safety: You can use many safe and non-safe signals under just a single address

 

Discover now our new ASi-5/ASi-3 Gateway family with integrated ASi-5 Safety - as well as the first ASi-5 Safety input modules, each with 4 x 1 channel or 2 x 2 channel safe inputs and up to 12 standard signals. With them, you can, for example, implement cost-effectively the connection of an operating panel to ASi - with several light buttons, an emergency stop button and a safe key switch.

 

The first configurable ASi-5 Safety Module with up to 14 safe inputs and 2 safe outputs (up to PLe) is a true “all-rounder”. The safe inputs can be configured for almost any sensor, whether OSSD or floating contacts – each as standard or antivalent switches. Thanks to this maximum flexibility, you can use the I/O module for almost all safety applications. Another advantage: Cyclic diagnostics of the safe inputs and outputs are always provided.

Modern ASi-5 Safety Gateways

ASi-5/ASi-3 Safety Gateways are currently the most advanced ASi masters – thanks in part to their chip card, which makes it easy to replace devices: if you insert the card into a new gateway with the same article number, all previous information is transferred: the safety and hardware configuration, parameter data of connected devices, and user comments. Many different variants are available: ASi-5/ASi-3 Safety Gateways for Ethernet-based fieldbus systems with and without safe fieldbus communication and with and without integrated safe local I/Os.

 

Product selector

Configurable ASi-5 Safety I/O Module
for flexible use in almost all applications

The first flexibly configurable ASi-5 Safety Module BWU4277 with up to 14 safe inputs and 2 safe outputs (up to PLe) can be used for almost all safety applications. The safe inputs can be configured for almost any sensor, whether OSSD or floating contacts – in each case as standard or antivalent switches.

ASi-5 Safety input modules
cost-saving for many applications

The ASi-5 Safety Modules with 2 safe inputs are comparable in price with our ASi-5 modules, which only have standard I/Os. This allows you to significantly reduce machine costs.

 

Product selector

ASi network with ASi-5 and ASi-3 products

FAQs about ASi-5

No. ASi-5 is the evolution of the well-proven AS-Interface standard. ASi-5 offers all the advantages that have already made ASi so special in the past. For example, power and data are still transmitted over a single cable, you have free choice of your topology and the safety technology is still on the same infrastructure. The main reason for evolving ASi was the fact that Industry 4.0 and increasing digitalization brings with it ever greater volumes of data. ASi-5 has both a large data size and short cycle times, making it possible to transport more and more data, without restrictions, to where they can yield valuable information.

Yes. ASi-5 is compatible with all earlier ASi devices and components, meaning that ASi-5 nodes  can be combined with ASi nodes of any generation—in existing as well as in new ASi networks. In an existing ASi network, you can simply connect additional new ASi-5 slaves and easily continue to use existing ASi nodess. To use ASi-5 nodes all you need is a new Bihl+Wiedemann ASi-5 / ASi-3 gateway.

ASi-3 directly follows ASi-5. “Skipping” ASi-4 illustrates that this development step is really big. In addition, we did not want to suggest that Industry 4.0 is the sole innovation driver for the new ASi generation.

In particular for applications with high transmission speeds or high data volumes. In addition, in places where a concentrated and cost-efficient collection of a larger number of inputs and outputs is needed. In many cases, Bihl+Wiedemann’s new digital ASi-5 modules can be an affordable alternative to other fieldbus solutions.

Yes. AS-Interface remains a standard ensuring compatibility with components from any manufacturer. All certified products with an ASi logo can interoperate in a common network.

No. In principle, they can be configured without software but we always recommend the more comfortable option using our software solutions. Our software Suite enables you to easily plan, configure and parameterize ASi networks with or without safety. If you already use the software for your ASi network, all you need is a free update to be able to continue using it for ASi-5 applications. The software is as intuitive and comfortable to use as with ASi-3. An integrated hardware catalogue encompasses the complete ASi product range. All you need to do is click the device you need when configuring the ASi circuit. The new online bus information also enables you to easily address slaves and monitor inputs and outputs. This function makes it even easier to integrate IO-Link sensors.

Like all ASi generations, ASi-5 is a joint development of several manufacturers of AS-Interface products. The complete project took more than 200,000 developer hours, evolving the idea of a new ASi generation into a mature trendsetting technology. Now that the main project has been completed, the involved companies continue to work on standards and certifications for new ASi-5 products.

By combining ASi-5 and ASi-3 slaves on one ASi circuit, it is possible to connect at least 62 nodes – in many cases, even considerably more.

 

The Bihl+Wiedemann hardware catalog tells you how many ASi nodes can be connected for specific applications. It is integrated in our ASIMON360 and ASi Control Tools360 software. So a warning appears if the maximum possible number of ASi-5 and ASi-3 slaves is exceeded. In addition, vacant ASi-5 transport channels can be shown at any time when planning.

 

Our experts will gladly answer any further questions you may have.

Yes, the use of ASi-5/ASi-3 gateways brings advantages in any case – even if you do not (yet) use ASi-5 nodes. This is because the new ASi-5/ASi-3 gateways are also the most performant ASi-3 gateways. Their advantages:

 

  • Field update capability: Firmware and security updates are installed in a tamper-proof way; new functions are quickly available. Users decide for themselves which updates they want to install on the gateways and slaves of their choice.
  • Integrated OPC UA server: Data from the field level can be transmitted directly and easily to Industry 4.0 applications.
  • Integrated web server: among other things, it enables fast system diagnostics via remote maintenance or convenient addressing of the slaves during commissioning.
  • Cyber security: The Ethernet fieldbus and Ethernet diagnostic interface are subjected to strict load tests by means of the Achilles test software Level 1 and 2 (Version 3.18); end-to-end encryption takes place via the Bihl+Wiedemann server.

The replacement device must have the same part number. You can then replace the defective node  without using a hand-held addressing device or additional programming work. The additional steps necessary depend on the slave type used (e.g. standard or safety). You can find more information in our video tutorial.

 

If you encounter problems or issues related to this topic, please contact our support team. Our product specialists will be happy to assist you.

 

Tel.: +49 621 33996-0
E-Mail: mailbihl-wiedemann.de

The replacement device must have the same part number. You can then replace the defective master without additional programming work. Please attach to the following necessary steps:

 

  1. Disconnect the defective safety monitor from the power supply and from the ASi network.
  2. Remove the chip card from the top of the defective unit and insert it into the replacement unit.
  3. Connect the new monitor to the ASi network and the power supply.
  4. The display menu of the monitor willguide you through the copying process to help you transfer the stored configuration from the chip card to the device.
  5. You may be asked to specify the direction in which the copying process is to be started – in this case, select "Chipcard > Master".
  6. Enter the release code of the configuration and confirm this code. The safety monitor then starts and the transfer is completed.


The above steps are described in detail in our video tutorial.

 

If you encounter problems, please contact our support team. Our product specialists will be happy to assist you.

 

Tel.: +49 621 33996-0
E-Mail: mailbihl-wiedemann.de

Already during the development of ASi-5 we made sure that IO-Link will be perfectly embedded in ASi-5 and our user-friendly PC software - from the device to the PLC or cloud.

Our mature concept enables IO-Link data to be transmitted transparently via ASi-5. The fieldbus-independent solution combines the advantages of IO-Link and ASi-5, allowing up to 64 ASi-5 modules, each with 1, 2, 4 or 8 IO-Link ports, to be connected to an ASi-5 master. The maximum possible data frame of an IO-Link device (32 bytes) can be mapped without any problems.

Thanks to ASi, you also benefit from drastically reduced wiring effort without swichtes, great freedom in the choice of topology, and a smart power supply concept.

 

 

You can find more information here.

This could also be of interest to you

Self-configuring I/O modules

The modules can be used flexibly and are cost-effective, making them a good alternative to comparable Ethernet or IO-Link-based I/O solutions.

ASi-5/ASi-3 Address Programming Device

Learn more about the user-friendly ASi-5/ASi-3 address programming device for easy addressing of modules of all ASi generations.

Drive solutions with ASi-5

Our drive solutions based on ASi-5 are characterized by short cycle times and high data size. Discover our ASi-5 motor modules for leading manufacturers, such as Lenze, Interroll and SEW-EURODRIVE.

AS-Interface

The standardized fieldbus system AS-Interface (ASi) helps you drastically reduce your wiring complexity. You also benefit from free choice of topology and cost-effective integration of safety features on the same infrastructure.

Do you have questions about ASi-5?

ASi – A resource-saving technology

Thanks to the greatly reduced wiring effort with AS-Interface, you save assembly and material costs. This saves valuable resources.

 

More information!