BWU3534Active Distributor ASi, IP67, 1I/4O

Product description

Active Distributor ASi, IP67, housing depth 35 mm, 1 digital input, 4 digital outputs, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 1 x M12 cable socket, straight, 5 poles and 1 x M12 cable socket, angled, 5 poles, cable length 0,3 m, flat design, installation in cable duct possible (installation depth > 35 mm), LED, connections for 1 x ASi profile cable, ASi connection via profile cable and piercing technology, 1 AB address

Technical data

Inputs Safety

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

no local safe inputs
Safety signal inputs no Safety signal inputs
Safety signal outputs no Safety signal outputs
Input voltage (sensor supply)

inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

out of ASi
Output voltage (actuator supply)

Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

out of ASi
ASi address

Bihl+Wiedemann offers modules with AB address, single address or ASi-5 address. In some cases, ASi modules can occupy several (different) addresses. Mixed operation of modules with different addressing in the same ASi circuit is permitted.
For ASi modules with two ASi-3 nodes, the second ASi-3 node is turned off as long as the first ASi-3 node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

1 AB address
Special function to connect Banner K50 Series EZ-Light, type K50L...PQ + Wenglor light curtains Pick-to-Light