Schneider Electric Drives
Bihl+Wiedemann is a member of Schneider Electric's "Technology Partner Program". In the following article overview you will find Bihl+Wiedemann products that are compatible with the safe drives of the Schneider Electric company.
Bihl+Wiedemann ASi Sercos Gateways with intergrated Safety Monitor
- compatible for use with safe drives from Schneider Electric
Figure | Model | Type | Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:
| Safety communication | Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.
| Suitable for applications up to category 4/PLe/SIL 3. | The device communicates via the standard ASi-3 and/or ASi-5. | Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|
Gateway with integrated Safety Monitor
|
Safety, Sercos ASi-5/ASi-3
|
OPC UA, REST API, Sercos
|
Safe Link, safe Schneider drives over Sercos
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
| BWU3861 ASi-5/ASi-3 safe Schneider drives over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters | |
Gateway with integrated Safety Monitor
|
Safety, Sercos
|
Sercos
|
Safe Link, safe Schneider drives over Sercos
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 4 A/ASi network
| BWU2984 ASi-3 safe Schneider drives over Sercos Gateway with integrated Safety Monitor, 2 ASi masters |