Archives I/O Modules

Archives Digital Modules in IP20

Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

Single wiring: 1 input or output per connection.

 

Y wiring: 2 inputs or outputs per connection.

 

Mixed wiring: 1 input and 1 output per connection.

 

Exact pin assignment see data sheet.
 

M8/M12 wiring

inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)
Connection

The connection to ASi and AUX (24 V auxiliary power) is made for modules in the active distributor or blue IP67 housing via the yellow or black ASi profile cable with piercing technology or via an M12 plug. Modules for the control cabinet are connected via terminals and PCB modules via wiring pins, connection wires or terminals.


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection

Bihl+Wiedemann offers modules with AB address, single address or ASi-5 address. In some cases, ASi modules can occupy several (different) addresses. Mixed operation of modules with different addressing in the same ASi circuit is permitted.
For ASi modules with two ASi-3 nodes, the second ASi-3 node is turned off as long as the first ASi-3 node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Article No.
BW2078
Stainless Steel in IP20, depth: 45 mm
depth: 45 mm
IP20
no digital inputs
8 x electronic
no M8/M12 wiring
no input voltage
out of AUX
spring type terminals
spring type terminals
2 AB addresses
BWU1938
IP20, 22,5 mm x 114 mm, 4 x 4 contacts
4 x COMBICON
IP20
4
4 x electronic
no M8/M12 wiring
out of AUX
out of AUX
push in terminals
Push-in terminals
1 AB address
BWU4183
IP20, 22,5 mm x 92 mm, 4 x 4 contacts
22.5 mm x 99.0 mm x 92.0 mm, 4 x 4 contacts
IP20
4
3 x electronic
no M8/M12 wiring
out of AUX
out of AUX
push in terminals
Push-in terminals
1 AB address
BW4968
IP20, 22,5 mm x 114 mm
22,5 mm x 114 mm
IP20
4
4 x electronic
no M8/M12 wiring
out of AUX
out of AUX
pluggable terminals
pluggable terminals
1 AB address
BW5053
IP20, 22,5 mm x 114 mm, 4 x 4 contacts
4 x COMBICON
IP20
4 (NPN)
4 x electronic (NPN)
no M8/M12 wiring
out of AUX
out of AUX
push in terminals
Push-in terminals
1 AB address
BWU4269
IP20, 22,5 mm x 114 mm, 6 x 4 contacts
22.5 mm x 99.0 mm x 114.5 mm, 6 x 4 contacts
IP20
4
4 x electronic
no M8/M12 wiring
out of ASi
out of AUX
push in terminals
Push-in terminals
1 Single address
BWU4270
IP20, 22,5 mm x 114 mm, 6 x 4 contacts
22.5 mm x 99.0 mm x 114.5 mm, 6 x 4 contacts
IP20
4
4 x electronic
no M8/M12 wiring
out of ASi
out of AUX
push in terminals
Push-in terminals
1 AB address

 

 

Archives Digital Modules in IP67

Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

Single wiring: 1 input or output per connection.

 

Y wiring: 2 inputs or outputs per connection.

 

Mixed wiring: 1 input and 1 output per connection.

 

Exact pin assignment see data sheet.
 

M8/M12 wiring

inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)
Connection

The connection to ASi and AUX (24 V auxiliary power) is made for modules in the active distributor or blue IP67 housing via the yellow or black ASi profile cable with piercing technology or via an M12 plug. Modules for the control cabinet are connected via terminals and PCB modules via wiring pins, connection wires or terminals.


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection

Bihl+Wiedemann offers modules with AB address, single address or ASi-5 address. In some cases, ASi modules can occupy several (different) addresses. Mixed operation of modules with different addressing in the same ASi circuit is permitted.
For ASi modules with two ASi-3 nodes, the second ASi-3 node is turned off as long as the first ASi-3 node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Article No.
BWU3145
IP67, 4 x M12, EXTREME
4 x M12
IP67
4
no digital outputs
Y
out of ASi
no output voltage
4 x M12 sockets, 5 poles
ASi profile cable
1 AB address
BWU3144
IP67, 8 x M12, EXTREME
8 x M12
IP67
4
4 x electronic
Y
out of ASi
out of AUX
8 x M12 sockets, 5 poles
ASi profile cable
1 AB address
BWU3449
IP67, 4 x M12
4 x M12
IP67
2
2 x electronic, special ASi bit assignment
Y
out of ASi
out of AUX
4 x M12 sockets, 5 poles
ASi profile cable
1 AB address
BWU4382
IP67, 8 x M12
8 x M12
IP67
4
3 x electronic
Y
out of ASi
out of AUX
8 x M12 sockets, 5 poles
ASi profile cable
1 AB address
BWU3895
IP67, 8 x M12
8 x M12
IP67
4
4 x electronic
Y
out of ASi
out of AUX, 2 A per output
8 x M12 sockets, 5 poles
ASi via M12
1 Single address
BWU4383
IP67, 8 x M12
8 x M12
IP67
4
4 x electronic
Single
out of ASi
out of AUX
8 x M12 sockets, 5 poles
ASi profile cable
1 Single address
BWU4415
IP67, 8 x M12
8 x M12
IP67
4
4 x electronic
Single
out of ASi
out of AUX
8 x M12 sockets, 5 poles
ASi via M12
1 Single address (S-7.0.F.E)

 

 

Archive digital modules in IP67 - replacement compatible with Schneider Electric

Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

Single wiring: 1 input or output per connection.

 

Y wiring: 2 inputs or outputs per connection.

 

Mixed wiring: 1 input and 1 output per connection.

 

Exact pin assignment see data sheet.
 

M8/M12 wiring

inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)
Connection

The connection to ASi and AUX (24 V auxiliary power) is made for modules in the active distributor or blue IP67 housing via the yellow or black ASi profile cable with piercing technology or via an M12 plug. Modules for the control cabinet are connected via terminals and PCB modules via wiring pins, connection wires or terminals.


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection

Bihl+Wiedemann offers modules with AB address, single address or ASi-5 address. In some cases, ASi modules can occupy several (different) addresses. Mixed operation of modules with different addressing in the same ASi circuit is permitted.
For ASi modules with two ASi-3 nodes, the second ASi-3 node is turned off as long as the first ASi-3 node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address

The node profiles allow numerous quickly configurable settings to be made on the module in order to optimally support the connected peripherals in most applications. The easiest way to select the node profiles is via the PC software.

If ID1 is in brackets (), this means it is the changeable default value; if ID1 is without brackets, it means it is a fixed, unchangeable value.

ASi node profile

Required profile that the ASi master needs to have in order to connect and operate the module.

Required Master profile
Article No.
BWU3682
IP67, 4 x M12
4 x M12
IP67
4
no digital outputs
standard
out of ASi
no output voltage
4 x M12 sockets, 5 poles
ASi profile cable
1 Single address
S-0.0.F.E
M0 ... M4
BWU3701
IP67, 8 x M12
8 x M12
IP67
4
3 x electronic
standard
out of ASi
out of AUX, 2 A per output
8 x M12 sockets, 5 poles
ASi profile cable
1 AB address
S-7.A.(7).0
M3 .. M4
BWU3686
IP67, 8 x M12
8 x M12
IP67
4
4 x electronic
standard
out of ASi
out of AUX, 2 A per output
8 x M12 sockets, 5 poles
ASi profile cable
1 Single address (S-7.0.F.E)
S-7.0.(F).E
M0 ... M4
BWU3523
IP67, 8 x M12
8 x M12
IP67
8
no digital outputs
dual (Y)
out of ASi
no output voltage
8 x M12 sockets, 5 poles
ASi profile cable
2 AB addresses
S1-0.A.(7).2, S2-0.A.(7).2
M3 .. M4

Archiv: Active Distributor ASi, IP67/IP54/IP20

Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)
Connection

Single wiring: 1 input or output per connection.

 

Y wiring: 2 inputs or outputs per connection.

 

Mixed wiring: 1 input and 1 output per connection.

 

Exact pin assignment see data sheet.
 

M8/M12 wiring

Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled.

In the case of the active distributors (ASi modules) however only the one ASi profile cable is counted.

Round cable

Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation.

Flat design, installation in cable duct possible

The module has connections for ASi and/or AUX profile cables to supply data and (auxiliary) power. Depending on the design, the devices also have an integrated profile cable derivation.

Profile cable connection

The connection to ASi and AUX (24 V auxiliary power) is made for modules in the active distributor or blue IP67 housing via the yellow or black ASi profile cable with piercing technology or via an M12 plug. Modules for the control cabinet are connected via terminals and PCB modules via wiring pins, connection wires or terminals.


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection

Bihl+Wiedemann offers modules with AB address, single address or ASi-5 address. In some cases, ASi modules can occupy several (different) addresses. Mixed operation of modules with different addressing in the same ASi circuit is permitted.
For ASi modules with two ASi-3 nodes, the second ASi-3 node is turned off as long as the first ASi-3 node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Special function Article No.
BWU3625
Active distributor ASi
depth: 35 mm
IP67
1
no digital outputs
out of ASi
no output voltage
1 x M12 cable socket, angled, 5 poles
Single
2 m
yes, depth: 35 mm
1 x ASi
ASi profile cable
1 Single address
no special function
BWU4892
Active distributor ASi
depth: 35 mm
IP67
3
3 x electronic
out of ASi
out of ASi
1 x M12 cable socket, straight, 8 poles
no M8/M12 wiring
1 m
yes, depth: 35 mm
1 x ASi
ASi profile cable
1 AB address
no special function
BWU4905
Active distributor ASi
depth: 19 mm
IP67
1
no digital outputs
out of AUX
no output voltage
1 x M12 cable socket, straight, 8 poles
Single
2 m
yes, depth: 19 mm
1 x ASi, 1 x AUX 24 V
ASi profile cable
1 AB address
to connect Schmerzal AZM161 and Fortress amGardPro to ASi

 

 

Archives Analog Modules

Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs analog Outputs analog

inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

The connection to ASi and AUX (24 V auxiliary power) is made for modules in the active distributor or blue IP67 housing via the yellow or black ASi profile cable with piercing technology or via an M12 plug. Modules for the control cabinet are connected via terminals and PCB modules via wiring pins, connection wires or terminals.


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection

Bihl+Wiedemann offers modules with AB address, single address or ASi-5 address. In some cases, ASi modules can occupy several (different) addresses. Mixed operation of modules with different addressing in the same ASi circuit is permitted.
For ASi modules with two ASi-3 nodes, the second ASi-3 node is turned off as long as the first ASi-3 node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Article No.
BWU1345
IP20, 22,5 mm x 92 mm, 4 x 4 contacts
22.5 mm x 99.0 mm x 92.0 mm, 4 x 4 contacts
IP20
2 x 4 ... 20 mA/2 x 0 … 10 V
no analog outputs
selectable, out of ASi or out of AUX, Default out of ASi
no output voltage
Push-in terminals
1 Single address
BWU1727
IP20, 22,5 mm x 92 mm, 4 x 4 contacts
22.5 mm x 99.0 mm x 92.0 mm, 4 x 4 contacts
IP20
no analog input
2 x 0 … 20 mA/2 x 0 …10 V
no input voltage
selectable, out of ASi or out of AUX, default out of AUX
Push-in terminals
1 Single address
BWU1364
IP20, 25 mm x 105 mm, 6 x 4 contacts
25.0 mm x 105.0 mm x 114.5 mm, 6 x 4 contacts
IP20
4 x 4 … 20 mA
no analog outputs
out of ASi or out of AUX, auto switching
no output voltage
Push-in terminals
1 Single address
BWU1365
IP20, 25 mm x 105 mm, 6 x 4 contacts
25.0 mm x 105.0 mm x 114.5 mm, 6 x 4 contacts
IP20
4 x 0 ... 10 V
no analog outputs
out of ASi or out of AUX, auto switching
no output voltage
Push-in terminals
1 Single address
BWU1366
IP20, 25 mm x 105 mm, 6 x 4 contacts
25.0 mm x 105.0 mm x 114.5 mm, 6 x 4 contacts
IP20
no analog input
4 x 0 … 20 mA
no input voltage
out of ASi or out of AUX, auto switching
Push-in terminals
1 Single address
BWU1367
IP20, 25 mm x 105 mm, 6 x 4 contacts
25.0 mm x 105.0 mm x 114.5 mm, 6 x 4 contacts
IP20
no analog input
4 x 0 ... 10 V
no input voltage
out of ASi or out of AUX, auto switching
Push-in terminals
1 Single address
BWU2243
IP20, 25 mm x 105 mm, 6 x 4 contacts
25.0 mm x 105.0 mm x 114.5 mm, 6 x 4 contacts
IP20
4 x thermocouple type K
no analog outputs
out of ASi
no output voltage
Push-in terminals
1 Single address
BWU1726
IP20, 22,5 mm x 92 mm, 4 x 4 contacts
22.5 mm x 99.0 mm x 92.0 mm, 4 x 4 contacts
IP20
2 x 4 ... 20 mA/2 x 0 … 10 V
no analog outputs
out of ASi
no output voltage
Push-in terminals
1 Single address
BWU2481
IP20, 25 mm x 105 mm, 6 x 4 contacts
25.0 mm x 105.0 mm x 114.5 mm, 6 x 4 contacts
IP20
4 x Pt1000
no analog outputs
out of ASi
no output voltage
Push-in terminals
1 Single address
BWU1465
IP65, 3 x PG
3 x PG
IP65
Load cell
no analog outputs
out of ASi
no output voltage
ASi profile cable
1 Single address
BWU2240
IP65, 3 x PG
3 x PG
IP65
Load cell
no analog outputs
out of ASi
no output voltage
ASi profile cable
1 Single address
BWU2241
IP65, 8 x PG
8 x PG
IP65
4 x Pt100
no analog outputs
out of ASi
no output voltage
ASi profile cable
1 Single address
BWU1893
IP65, 2 x M12, width: 45 mm
width: 45 mm
IP65
2 x 4 … 20 mA
no analog outputs
out of ASi
no output voltage
ASi profile cable
1 AB address
BWU1894
IP65, 2 x M12, width: 45 mm
width: 45 mm
IP65
2 x 4 … 20 mA
no analog outputs
out of ASi
no output voltage
ASi profile cable
1 Single address
BWU1963
IP65, 2 x M12, width: 45 mm
width: 45 mm
IP65
2 x 0 ... 10 V
no analog outputs
out of ASi
no output voltage
ASi profile cable
1 AB address
BWU1964
IP65, 2 x M12, width: 45 mm
width: 45 mm
IP65
2 x 0 ... 10 V
no analog outputs
out of ASi
no output voltage
ASi profile cable
1 Single address
BWU1895
IP65, 2 x M12, width: 45 mm
width: 45 mm
IP65
2 x Pt100
no analog outputs
out of ASi
no output voltage
ASi profile cable
1 AB address
BWU1897
IP20, 22,5 mm x 92 mm, 4 x 4 contacts
22.5 mm x 99.0 mm x 92.0 mm, 4 x 4 contacts
IP20
2 x 4 ... 20 mA/2 x 0 … 10 V
no analog outputs
selectable, out of ASi or out of AUX, Default out of ASi
no output voltage
Push-in terminals
1 AB address
BWU1917
IP65, 4 x M12, width: 90 mm
width: 90 mm
IP65
1 x 4 … 20 mA/0 … 10 V
1x 0 … 20 mA
out of ASi
out of ASi
ASi profile cable
2-4 Single addresses
BWU1853
IP65, 4 x M12, width: 90 mm
width: 90 mm
IP65
1 x 4 … 20 mA/0 … 10 V
1 x 0 ... 20 mA/0 ... 10 V
out of AUX
out of AUX
ASi profile cable
2-4 Single addresses
BWU1359
IP65, 4 x M12, width: 90 mm
width: 90 mm
IP65
4 x 4 … 20 mA
no analog outputs
out of ASi or out of AUX, auto switching
no output voltage
ASi profile cable
1 Single address
BWU1360
IP65, 4 x M12, width: 90 mm
width: 90 mm
IP65
4 x 0 ... 10 V
no analog outputs
out of ASi or out of AUX, auto switching
no output voltage
ASi profile cable
1 Single address
BWU1363
IP65, 4 x M12, width: 90 mm
width: 90 mm
IP65
4 x Pt100, 2/4 wire mode
no analog outputs
out of ASi
no output voltage
ASi profile cable
1 Single address
BWU2532
IP65, 4 x M12, width: 90 mm
width: 90 mm
IP65
4 x Pt100, 2/3 wire mode
no analog outputs
out of ASi
no output voltage
ASi profile cable
1 Single address
BWU1722
IP65, 4 x M12, width: 90 mm
width: 90 mm
IP65
no analog input
4 x 0 … 20 mA
no input voltage
out of AUX
ASi profile cable
1 Single address
BWU1361
IP65, 4 x M12, width: 90 mm
width: 90 mm
IP65
no analog input
4 x 0 … 20 mA
no input voltage
out of ASi or out of AUX, auto switching
ASi profile cable
1 Single address
BWU1362
IP65, 4 x M12, width: 90 mm
width: 90 mm
IP65
no analog input
4 x 0 ... 10 V
no input voltage
out of ASi or out of AUX, auto switching
ASi profile cable
1 Single address
BWU2857
IP65, 4 x M12, width: 90 mm
width: 90 mm
IP65
no analog input
4 x 0 … 10 V; 24 V, 0 V via M12
no input voltage
out of ASi or out of AUX, auto switching
ASi profile cable
1 Single address