Building Automation
Building Automation
Figure |
Type
|
Inputs digital
|
Outputs digital
|
Inputs analog
|
Outputs analog
|
Input voltage (sensor supply)
|
Output voltage (actuator supply)
|
Protection rating
|
Special function
| |
---|---|---|---|---|---|---|---|---|---|---|
110...240 VAC, 2 ASi circuits
|
8
|
8 x relay
|
no analog input
|
no analog outputs
|
out of ASi
|
out of ASi
|
IP65
|
to control of up to 240 fire dampers
| ||
110...240 VAC, 1 ASi circuit
|
4
|
4 x relay
|
no analog input
|
no analog outputs
|
out of ASi
|
out of ASi
|
IP65
|
to control of up to 120 fire dampers
| ||
Control program for fire damper "Stand alone" control unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
| ||
-
|
-
|
-
|
-
|
-
|
out of ASi
|
out of ASi
|
IP65
|
for circuit extension by up to 200 m
| ||
ventilation damper module
|
4
|
2 x electronic
|
-
|
-
|
out of ASi
|
out of ASi
|
IP54
|
Meets requirements for Germany and EU
| ||
ventilation damper module
|
4
|
2 x electronic
|
-
|
-
|
out of ASi
|
out of ASi
|
IP54
|
Meets requirements for Germany and EU
| ||
ventilation damper module
|
3
|
2 x electronic
|
-
|
-
|
out of ASi
|
out of ASi
|
IP54
|
Meets requirements for Switzerland (IG-BSK)
| ||
ventilation damper module
|
3
|
2 x electronic
|
-
|
-
|
out of AUX
|
out of AUX
|
IP54
|
Meets requirements for Germany and EU
| ||
ventilation damper module, Safety
|
4
|
2 x electronic
|
-
|
-
|
out of ASi
|
out of ASi
|
IP40
|
Meets requirements for Germany and EU
| ||
ventilation damper module, Safety
|
4
|
2 x electronic
|
-
|
-
|
out of ASi
|
out of ASi
|
IP40
|
Meets requirements for Germany and EU
| ||
ventilation damper module
|
4
|
4 x relay
|
-
|
-
|
out of ASi
|
-
|
IP54
|
230 V relay
| ||
ventilation damper module
|
4 + 2 x fusible link
|
2 x relay
|
-
|
-
|
out of ASi
|
-
|
IP54
|
230 V relay
| ||
ventilation damper module
|
4
|
2 x relay
|
-
|
-
|
out of ASi
|
-
|
IP54
|
230 V relay
| ||
ventilation damper module
|
4
|
-
|
-
|
-
|
out of ASi
|
-
|
IP54
|
-
| ||
shutter module
|
8
|
4 x relay
|
-
|
-
|
out of ASi
|
-
|
IP54
|
to control 230 V shutters/blinds
| ||
shutter module
|
8
|
4 x relay
|
-
|
-
|
out of ASi
|
-
|
IP40
|
to control 230 V shutters/blinds
| ||
Surface-mounted box, IP54
|
4
|
4 x electronic
|
-
|
-
|
out of AUX
|
out of AUX
|
IP54
|
-
| ||
Surface-mounted box, IP54
|
4
|
4 x electronic
|
-
|
-
|
out of AUX
|
out of AUX
|
IP54
|
-
| ||
Surface-mounted box, IP54
|
4
|
3 x electronic
|
-
|
-
|
out of AUX
|
out of AUX
|
IP54
|
-
| ||
Surface-mounted box, IP54
|
4
|
4 x electronic
|
-
|
-
|
out of AUX
|
out of AUX
|
IP54
|
for manual call points
| ||
Surface-mounted box, IP54
|
-
|
-
|
1 x 0 ... 10 V
|
1x 0 … 10 V
|
selectable, out of ASi or out of AUX, Default out of ASi
|
selectable, out of ASi or out of AUX, default out of ASi
|
IP54
|
for air volume terminal units
| ||
heating/air conditioning (24 V AC/DC)
|
2
|
-
|
2 x 0 ... 10 V
|
-
|
selectable, out of ASi or out of AUX (AC/DC), default out of ASi
|
-
|
IP54
|
analog inputs 0 ... 10 V (temperature CO2 etc.) + digital inputs
| ||
heating/air conditioning (24 V AC/DC)
|
-
|
2 x electronic
|
-
|
2 x 0 … 10 V
|
out of ASi
|
selectable, out of ASi or out of AUX (AC/DC), default out of ASi
|
IP54
|
for heating/air conditioning (climate ceilings)
| ||
Heating/air conditioning
|
-
|
4 x electronic
|
-
|
-
|
-
|
out of AUX
|
IP54
|
-
| ||
connection to EnOcean
|
31 x 4
|
EnOcean
|
8 x 6
|
EnOcean
|
out of ASi
|
-
|
IP40
|
-
| ||
connection to EnOcean
|
31 x 4
|
EnOcean
|
8 x 6
|
EnOcean
|
out of ASi
|
-
|
IP40
|
-
| ||
connection to EnOcean
|
31 x 4
|
EnOcean
|
8 x 6
|
EnOcean
|
out of ASi
|
-
|
IP40
|
-
| ||
connection to MP-Bus
|
-
|
-
|
-
|
-
|
out of ASi
|
out of AUX
|
IP54
|
-
| ||
PCB building automation
|
4
|
4 x electronic
|
-
|
-
|
out of ASi
|
out of ASi
|
IP00, thick coated
|
-
| ||
PCB building automation
|
4
|
-
|
-
|
-
|
out of ASi
|
-
|
IP00, thick coated
|
-
| ||
PCB building automation
|
4
|
3 x electronic
|
-
|
-
|
out of AUX
|
out of AUX
|
IP00
|
-
| ||
IP65, 8 x PG
|
-
|
-
|
4 x Pt100
|
-
|
out of ASi
|
-
|
IP65
|
-
| ||
IP65, 8 x PG
|
-
|
-
|
4 x Pt1000
|
-
|
out of ASi
|
-
|
IP65
|
-
| ||
IP65, 3 x PG
|
-
|
-
|
2 x 4 … 20 mA
|
-
|
selectable, out of ASi or out of AUX, Default out of ASi
|
-
|
IP65
|
-
| ||
IP65, 3 x PG
|
-
|
-
|
2 x 0 ... 10 V
|
-
|
selectable, out of ASi or out of AUX, Default out of ASi
|
-
|
IP65
|
-
| ||
IP65, 3 x PG
|
-
|
-
|
-
|
2 x 0 ... 20 mA
|
-
|
selectable, out of ASi or out of AUX, default out of ASi
|
IP65
|
-
| ||
IP65, 3 x PG
|
-
|
-
|
-
|
2 x 0 … 10 V
|
-
|
selectable, out of ASi or out of AUX, default out of ASi
|
IP65
|
-
| ||
Stainless Steel in IP20, depth: 45 mm
|
8
|
no digital outputs
|
no analog input
|
no analog outputs
|
out of AUX
|
no output voltage
|
IP20
|
no special function
| ||
Stainless Steel in IP20, depth: 90 mm
|
8
|
no digital outputs
|
no analog input
|
no analog outputs
|
out of AUX
|
no output voltage
|
IP20
|
no special function
| ||
Stainless Steel in IP20, depth: 45 mm
|
4
|
4 x electronic
|
no analog input
|
no analog outputs
|
out of AUX
|
out of AUX
|
IP20
|
no special function
| ||
Stainless Steel in IP20, depth: 45 mm
|
4
|
4 x electronic
|
no analog input
|
no analog outputs
|
out of AUX
|
out of AUX
|
IP20
|
no special function
| ||
Stainless Steel in IP20, depth: 45 mm
|
4
|
4 x relay
|
no analog input
|
no analog outputs
|
out of ASi
|
-
|
IP20
|
no special function
| ||
Stainless Steel in IP20, depth: 90 mm
|
4
|
4 x relay
|
no analog input
|
no analog outputs
|
out of ASi
|
-
|
IP20
|
no special function
| ||
Stainless Steel in IP20, depth: 45 mm
|
4
|
3 x relay
|
no analog input
|
no analog outputs
|
out of ASi
|
-
|
IP20
|
no special function
| ||
IP20, 25 mm x 105 mm, 6 x 4 contacts
|
no digital inputs
|
no digital outputs
|
4 x thermocouple type J
|
no analog outputs
|
out of ASi
|
no output voltage
|
IP20
|
no special function
| ||
IP20, 25 mm x 105 mm, 6 x 4 contacts
|
no digital inputs
|
no digital outputs
|
4 x thermocouple type K
|
no analog outputs
|
out of ASi
|
no output voltage
|
IP20
|
no special function
| ||
IP20, 22,5 mm x 114 mm, 6 x 4 contacts, ASi-5
|
16
|
no digital outputs
|
no analog input
|
no analog outputs
|
out of AUX
|
no output voltage
|
IP20
|
no special function
| ||
IP20, 22,5 mm x 114 mm, 6 x 4 contacts, ASi-5
|
8
|
8 x electronic
|
no analog input
|
no analog outputs
|
out of AUX
|
out of AUX
|
IP20
|
no special function
| ||
IP20, 22,5 mm x 114 mm, 6 x 4 contacts, ASi-5
|
8
|
no digital outputs
|
no analog input
|
no analog outputs
|
out of AUX
|
no output voltage
|
IP20
|
no special function
| ||
IP20, 22,5 mm x 114 mm, 6 x 4 contacts
|
8
|
8 x electronic
|
no analog input
|
no analog outputs
|
out of ASi
|
out of AUX
|
IP20
|
no special function
| ||
IP20, 22,5 mm x 114 mm, 6 x 4 contacts
|
8
|
8 x electronic
|
no analog input
|
no analog outputs
|
out of AUX
|
out of AUX
|
IP20
|
no special function
| ||
IP20, 22,5 mm x 114 mm, 6 x 4 contacts
|
8
|
8 x electronic
|
no analog input
|
no analog outputs
|
out of AUX
|
out of AUX
|
IP20
|
no special function
| ||
IP20, 22,5 mm x 114 mm, 4 x 4 contacts
|
8
|
no digital outputs
|
no analog input
|
no analog outputs
|
out of AUX
|
no output voltage
|
IP20
|
no special function
| ||
IP20, 22,5 mm x 114 mm, 4 x 4 contacts
|
4
|
4 x electronic
|
no analog input
|
no analog outputs
|
out of AUX
|
out of AUX
|
IP20
|
no special function
| ||
IP20, 22,5 mm x 114 mm, 4 x 4 contacts
|
4
|
4 x electronic
|
no analog input
|
no analog outputs
|
out of AUX
|
out of AUX
|
IP20
|
no special function
| ||
IP20, 22,5 mm x 114 mm, 6 x 4 contacts
|
4
|
4 x relay
|
no analog input
|
no analog outputs
|
out of ASi
|
no output voltage
|
IP20
|
no special function
| ||
IP20, 22,5 mm x 114 mm, 4 x 4 contacts
|
4
|
no digital outputs
|
no analog input
|
no analog outputs
|
out of AUX
|
no output voltage
|
IP20
|
no special function
| ||
IP20, 22,5 mm x 92 mm, 4 x 4 contacts
|
4
|
4 x electronic
|
no analog input
|
no analog outputs
|
out of AUX
|
out of AUX, 2 A per output
|
IP20
|
no special function
| ||
IP20, 22,5 mm x 92 mm, 4 x 4 contacts
|
4
|
4 x electronic
|
no analog input
|
no analog outputs
|
out of AUX
|
out of AUX
|
IP20
|