BWU3534Active Distributor ASi, IP67, 1I/4O
Product description
Active Distributor ASi, IP67, housing depth 35 mm, 1 digital input, 4 digital outputs, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 1 x M12 cable socket, straight, 5 poles and 1 x M12 cable socket, angled, 5 poles, cable length 0,3 m, flat design, installation in cable duct possible (installation depth > 35 mm), LED, connections for 1 x ASi profile cable, ASi connection via profile cable and piercing technology, 1 AB address
Technical data
Inputs digital | 1 |
Outputs digital | 4 x electronic |
Input voltage (sensor supply)
inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential. | out of ASi |
Output voltage (actuator supply)
Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.
For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet. | out of ASi |
Connection | 1 x M12 cable socket, angled, 5 poles, 1 x M12 cable socket, straight, 5 poles |
Round cable
Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled. In the case of the active distributors (ASi modules) however only the one ASi profile cable is counted. | 0,30 m |
Flat design, installation in cable duct possible
Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation. | yes, depth: 35 mm |
ASi address
Bihl+Wiedemann offers modules with AB address, single address or ASi-5 address. In some cases, ASi modules can occupy several (different) addresses. Mixed operation of modules with different addressing in the same ASi circuit is permitted. | 1 AB address |
Special function | to connect Banner K50 Series EZ-Light, type K50L...PQ + Wenglor light curtains Pick-to-Light |
How to get started with Bihl+Wiedemann products
How to easily implement your ASi installation
How to troubleshoot an existing ASi installation
Manuals
EPLAN Macros
Video Tutorial
Quick Start Guides
- Quick Start Guide: Tips & Tricks: Replacing a defective device (DE)
- Quick Start Guide: Tips & Tricks: Replacing a defective device (EN)
- Quick Start Guide: ASIMON360 Configuration of Safety devices (DE)
- Quick Start Guide: ASIMON360 Configuration of Safety devices (EN)
- Quick Start Guide: ASIMON360 Configuration of Safety devices (PL)