Archives Safety Monitor

Archive Safety Monitors, Safety Basic Monitor

Figure Type Model

The device communicates via the standard ASi-3 and/or ASi-5.

ASi-5/ASi-3

The device communicates safely via the standard ASi-3 Safety and/or ASi-5 Safety.

ASi Safety

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input.

Inputs digital, EDM

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety communication

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Connection

The connection to ASi and AUX (24 V auxiliary power) is made for modules in the active distributor or blue IP67 housing via the yellow or black ASi profile cable with piercing technology or via an M12 plug. Modules for the control cabinet are connected via terminals and PCB modules via wiring pins, connection wires or terminals.


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Article No.
BWU2441
Safety Basic Monitor
Safety Basic Monitor, Safety Basic Monitor with extended features
ASi-3 compatible
ASi-3 Safety capable
4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz), 4 x 2 channels, inputs 3+4 optional for standstill monitor
8
2 release circuits, 2 x electronic safe outputs
-
ASi monitors
1 ASi network, 1 ASi-3 Master
yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply
USB
no
no
no
push in terminals
Push-in terminals
IP20
BWU2569
Safety Basic Monitor
Safety Basic Monitor with extended features
ASi-3 compatible
ASi-3 Safety capable
4 x 2 channels, inputs 3+4 optional for standstill monitor
8
2 release circuits, 2 x electronic safe outputs
-
ASi monitors
1 ASi network, 1 ASi-3 Master
yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply
USB
no
no
no
push in terminals
Push-in terminals
IP20
BWU3505
Safety Basic Monitor
Safety Basic Monitor with extended features
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels, input 3 optional for speed monitor (up to 4 kHz)
6
2 release circuits, 2 x electronic safe outputs
dynamic position monitoring
ASi monitors
1 ASi network, 1 ASi-3 Master
yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply
Ethernet diagnostic
no
no
no
push in terminals
Push-in terminals
IP20
BWU3318
Safety Basic Monitor
Safety Basic Monitor
ASi-3 compatible
ASi-3 Safety capable
4 x 2 channels
-
2 release circuits, 2 x electronic safe outputs
no Safety communication
ASi monitors
-
no, max. 8 A/ASi network
USB
no
no
no
push in terminals (coded)
coded clamps
IP20
BWU3506
Safety Monitor in Stainless Steel
-
-
-
no local safe inputs
no local input
no local safe output
Safe Link, Shuttle Safety
-
-
-
Ethernet diagnostic
no
no
no
push in terminals
-
IP20
BWU3839
Safety Monitor in Stainless Steel
-
-
-
no local safe inputs
no local input
no local safe output
Safe Link, Shuttle Safety
REST API
-
-
Ethernet diagnostic
no
no
no
push in terminals
-
IP20

 

 

Archive Safety Monitors, Safety PROFIBUS

Figure Type Model

The device communicates via the standard ASi-3 and/or ASi-5.

ASi-5/ASi-3

The device communicates safely via the standard ASi-3 Safety and/or ASi-5 Safety.

ASi Safety

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input.

Inputs digital, EDM
Inputs safety, expandable to

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety outputs, independent according to SIL 3, expandable to Safety communication

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Article No.
BW2027
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
2
no expandable Safety inputs
2 release circuits, 2 x 2 relay
no expandable safety outputs
no Safety communication
PROFIBUS
2 ASi networks, 1 ASi-3 Master
no, max. 8 A/ASi network, redundant supply
no diagnostic interface
yes
yes
no
IP20
BWU2187
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
2 release circuits, 2 x 2 relay
max. 16
no Safety communication
PROFIBUS
2 ASi networks, 1 ASi-3 Master
no, max. 8 A/ASi network, redundant supply
RS 232
yes
yes
no
IP20
BWU2188
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
2 release circuits, 2 x 2 relay
max. 16
no Safety communication
PROFIBUS
2 ASi networks, 1 ASi-3 Master
yes, max. 4 A/ASi network
RS 232
yes
yes
no
IP20
BWU2535
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
no Safety communication
PROFIBUS
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
RS 232
yes
yes
optional
IP20
BWU2202
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
no Safety communication
PROFIBUS
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
no
IP20
BWU2204
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
no Safety communication
PROFIBUS
2 ASi networks, 1 ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
no
IP20
BWU2206
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
2 release circuits, 2 x 2 relay
max. 16
no Safety communication
PROFIBUS
2 ASi networks, 1 ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
no
IP20
BWU2602
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
PROFIBUS
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU2702
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
PROFIBUS
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU2002
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
no Safety communication
PROFIBUS
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
RS 232
yes
yes
no
IP20
BWU2001
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
no Safety communication
PROFIBUS
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
RS 232
yes
yes
no
IP20
BWU2003
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
no Safety communication
PROFIBUS
2 ASi networks, 1 ASi-3 Master
no, max. 8 A/ASi network, redundant supply
RS 232
yes
yes
no
IP20
BWU2004
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
no Safety communication
PROFIBUS
2 ASi networks, 1 ASi-3 Master
yes, max. 4 A/ASi network
RS 232
yes
yes
no
IP20
BWU2635
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
PROFIBUS
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU3275
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
PROFIBUS
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU2227
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
no Safety communication
PROFIBUS
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
RS 232
yes
yes
no
IP20
BWU2277
Safety, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
no Safety communication
PROFIBUS
2 ASi networks, 1 ASi-3 Master
no, max. 8 A/ASi network, redundant supply
RS 232
yes
yes
no
IP20

Archive Safety Monitors, Safety PROFINET

Figure Type Model

The device communicates via the standard ASi-3 and/or ASi-5.

ASi-5/ASi-3

The device communicates safely via the standard ASi-3 Safety and/or ASi-5 Safety.

ASi Safety

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input.

Inputs digital, EDM

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety communication

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Article No.
BWU3993
Safety, PROFINET ASi-5/ASi-3
Gateway with integrated Safety Monitor
ASi-3 compatible, ASi-5 compatible
ASi-3 Safety capable
3 x 2 channels
6
6 release circuits, 6 x electronic safe outputs
Safe Link
OPC UA, PROFINET, REST API
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU3992
Safety, PROFINET ASi-5/ASi-3
Gateway with integrated Safety Monitor
ASi-3 compatible, ASi-5 compatible
ASi-3 Safety capable
no local safe inputs
no local input
no local safe output
Safe Link
OPC UA, PROFINET, REST API
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU2534
Safety, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
4 release circuits, 2 x relay, 2 x electronic safe outputs
no Safety communication
PROFINET
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
Ethernet fieldbus, RS 232
yes
yes
no
IP20
BWU2237
Safety, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
4 release circuits, 2 x relay, 2 x electronic safe outputs
no Safety communication
PROFINET
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet fieldbus, RS 232
yes
yes
no
IP20
BWU2330
Safety, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
4 release circuits, 2 x relay, 2 x electronic safe outputs
no Safety communication
PROFINET
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
Ethernet fieldbus, RS 232
yes
yes
no
IP20
BWU2307
Safety, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
4 release circuits, 2 x relay, 2 x electronic safe outputs
no Safety communication
PROFINET
2 ASi networks, 1 ASi-3 Master
no, max. 8 A/ASi network, redundant supply
Ethernet fieldbus, RS 232
yes
yes
no
IP20
BWU2642
Safety, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
4 release circuits, 2 x relay, 2 x electronic safe outputs
Safe Link
PROFINET
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet fieldbus, RS 232
yes
yes
optional
IP20
BWU2634
Safety, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
6 release circuits, 6 x electronic safe outputs
Safe Link
PROFINET
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet fieldbus, RS 232
yes
yes
optional
IP20
BWU3274
Safety, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
6 release circuits, 6 x electronic safe outputs
Safe Link
PROFINET
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet fieldbus, RS 232
yes
yes
optional
IP20
BWU3080
Safety, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
6 release circuits, 6 x electronic safe outputs
Safe Link
PROFINET
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU3692
Safety, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
6 release circuits, 6 x electronic safe outputs
Safe Link
PROFINET
1 ASi network, 1 ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BW3000
Safety, Starter Kits
Starter Kits
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
6 release circuits, 6 x electronic safe outputs
Safe Link
PROFINET
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BW3074
Safety, Starter Kits
Starter Kits
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
6 release circuits, 6 x electronic safe outputs
Safe Link
PROFINET
1 ASi network, 1 ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU2633
Safety, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
no local input
no local safe output
Safe Link
PROFINET
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet fieldbus, RS 232
yes
yes
optional
IP20
BWU2798
Safety, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
6 release circuits, 6 x electronic safe outputs
Safe Link
PROFINET
1 ASi network, 1 ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU2828
Safety, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
6 release circuits, 6 x electronic safe outputs
Safe Link
PROFINET
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU3863
Safety, PROFINET ASi-5/ASi-3
Gateway with integrated Safety Monitor
ASi-3 compatible, ASi-5 compatible
ASi-3 Safety capable
3 x 2 channels
6
6 release circuits, 6 x electronic safe outputs
Safe Link
OPC UA, PROFINET, REST API
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU4000
Safety, PROFINET ASi-5/ASi-3
Gateway with integrated Safety Monitor
ASi-3 compatible, ASi-5 compatible
ASi-3 Safety capable
3 x 2 channels
6
6 release circuits, 6 x electronic safe outputs
Safe Link
OPC UA, PROFINET, REST API
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20

Archive Safety Monitors, Safety PROFIsafe

Figure Type Model

The device communicates via the standard ASi-3 and/or ASi-5.

ASi-5/ASi-3

The device communicates safely via the standard ASi-3 Safety and/or ASi-5 Safety.

ASi Safety

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input.

Inputs digital, EDM
Inputs safety, expandable to

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety outputs, independent according to SIL 3, expandable to Safety communication

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Article No.
BWU2214
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
PROFIsafe (F-CPU), no preprocessing in ASIMON
PROFIBUS
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
RS 232
yes
yes
no
IP20
BWU2215
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
PROFIsafe (F-CPU), no preprocessing in ASIMON
PROFIBUS
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
RS 232
yes
yes
no
IP20
BWU2615
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
PROFIsafe (F-CPU)
PROFIBUS
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU2598
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
PROFIsafe (F-CPU)
PROFIBUS
2 ASi networks, 1 ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU2479
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
no local input
max. 31 x 2 channels
no local safe output
max. 16
PROFIsafe (F-CPU), no preprocessing in ASIMON
PROFIBUS
1 ASi network, 1 ASi-3 Master
yes, max. 4 A/ASi network
RS 232
yes
yes
no
IP20
BWU2383
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
PROFIsafe (F-CPU), no preprocessing in ASIMON
PROFINET
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet fieldbus, RS 232
yes
yes
no
IP20
BWU2421
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
PROFIsafe (F-CPU), no preprocessing in ASIMON
PROFINET
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
Ethernet fieldbus, RS 232
yes
yes
no
IP20
BWU3823
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 64, max. 1984 in max. configuration
PROFIsafe (F-CPU), Safe Link
REST API
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU2647
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
PROFIsafe (F-CPU)
PROFINET
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet fieldbus, RS 232
yes
yes
optional
IP20
BWU3674
PROFIsafe, PROFINET, ASi-5 / ASi-3
Gateway with integrated Safety Monitor
ASi-3 compatible, ASi-5 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 64, max. 1984 in max. configuration
PROFIsafe (F-CPU), Safe Link
OPC UA, PROFINET, REST API
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU3833
PROFIsafe, PROFINET, ASi-5 / ASi-3
Gateway with integrated Safety Monitor
ASi-3 compatible, ASi-5 compatible
ASi-3 Safety capable
no local safe inputs
no local input
max. 62 x 2 channels, max. 1922 in max. configuration
no local safe output
max. 64, max. 1984 in max. configuration
PROFIsafe (F-CPU), Safe Link
OPC UA, PROFINET, REST API
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU3862
PROFIsafe, PROFINET, ASi-5 / ASi-3
Gateway with integrated Safety Monitor
ASi-3 compatible, ASi-5 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 64, max. 1984 in max. configuration
PROFIsafe (F-CPU), Safe Link
OPC UA, PROFINET, REST API
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU4018
PROFIsafe, PROFINET, ASi-5 / ASi-3
Gateway with integrated Safety Monitor
ASi-3 compatible, ASi-5 compatible
ASi-3 Safety capable
no local safe inputs
no local input
max. 31 x 2 channels, max. 1891 in max. configuration
no local safe output
max. 64, max. 1984 in max. configuration
PROFIsafe (F-CPU), Safe Link
OPC UA, PROFINET, REST API
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU3367
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 64, max. 1984 in max. configuration
PROFIsafe (F-CPU), Safe Link
PROFINET
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU2794
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 31 x 2 channels
6 release circuits, 6 x electronic safe outputs
max. 31
PROFIsafe (F-CPU)
PROFINET
1 ASi network, 1 ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU2805
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
no local input
max. 62 x 2 channels
no local safe output
max. 16
PROFIsafe (F-CPU)
PROFINET
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20

Archive Safety Monitors, Safety sercos

Figure Type Model

The device communicates via the standard ASi-3 and/or ASi-5.

ASi-5/ASi-3

The device communicates safely via the standard ASi-3 Safety and/or ASi-5 Safety.

ASi Safety

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input.

Inputs digital, EDM
Inputs safety, expandable to

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety outputs, independent according to SIL 3, expandable to Safety communication

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Article No.
BWU2758
Safety, Sercos
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels
6 release circuits, 6 x electronic safe outputs
max. 64
CIP Safety over Sercos
Sercos
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU3160
Safety, Sercos
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 64, max. 1984 in max. configuration
CIP Safety over Sercos, Safe Link
Sercos
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU2984
Safety, Sercos
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 64, max. 1984 in max. configuration
Safe Link, safe Schneider drives over Sercos
Sercos
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU2588
Safety, Sercos
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Sercos
2 ASi networks, 1 ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU3533
Safety, Sercos
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
no local input
max. 62 x 2 channels, max. 1922 in max. configuration
no local safe output
max. 64, max. 1984 in max. configuration
CIP Safety over Sercos, Safe Link
Sercos
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20

Archive Safety Monitors, Safety Ethernet/IP+ModbusTCP

Figure Type Model

The device communicates via the standard ASi-3 and/or ASi-5.

ASi-5/ASi-3

The device communicates safely via the standard ASi-3 Safety and/or ASi-5 Safety.

ASi Safety

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input.

Inputs digital, EDM
Inputs safety, expandable to

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety outputs, independent according to SIL 3, expandable to Safety communication

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Article No.
BWU3959
EtherNet/IP + Modbus TCP ASi-5/ASi-3
Gateway with integrated ASi-5/ASi-3 Safety Monitor
ASi-3 compatible, ASi-5 compatible
ASi-3 Safety capable, ASi-5 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 64, max. 1984 in max. configuration
Safe Link
EtherNet/IP, Modbus/TCP, OPC UA, REST API
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU3960
EtherNet/IP + Modbus TCP ASi-5/ASi-3
Gateway with integrated ASi-5/ASi-3 Safety Monitor
ASi-3 compatible, ASi-5 compatible
ASi-3 Safety capable, ASi-5 Safety capable
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
EtherNet/IP, Modbus/TCP, OPC UA, REST API
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU2267
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
no Safety communication
EtherNet/IP, Modbus/TCP
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet fieldbus, RS 232
yes
yes
optional
IP20
BWU2273
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
no Safety communication
EtherNet/IP, Modbus/TCP
2 ASi networks, 1 ASi-3 Master
no, max. 8 A/ASi network, redundant supply
Ethernet fieldbus, RS 232
yes
yes
optional
IP20
BWU2317
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
no Safety communication
EtherNet/IP, Modbus/TCP
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
Ethernet fieldbus, RS 232
yes
yes
optional
IP20
BWU2579
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
EtherNet/IP, Modbus/TCP
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU3683
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 64, max. 1984 in max. configuration
CIP Safety over EtherNet/IP, Safe Link
EtherNet/IP, Modbus/TCP, OPC UA, REST API
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU2742
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels
6 release circuits, 6 x electronic safe outputs
max. 64
CIP Safety over EtherNet/IP
EtherNet/IP, Modbus/TCP
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU2821
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
EtherNet/IP, Modbus/TCP
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU3079
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
EtherNet/IP, Modbus/TCP
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU2818
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
EtherNet/IP, Modbus/TCP
1 ASi network, 1 ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU3693
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
EtherNet/IP, Modbus/TCP, OPC UA, REST API
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU3542
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
EtherNet/IP, Modbus/TCP, REST API
1 ASi network, 1 ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU3543
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
EtherNet/IP, Modbus/TCP, REST API
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20
BWU3544
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
EtherNet/IP, Modbus/TCP, REST API
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
Ethernet diagnostic, Ethernet fieldbus
yes
yes
optional
IP20

Archive Safety Monitors, Safety EtherCAT

Figure Type Model

The device communicates via the standard ASi-3 and/or ASi-5.

ASi-5/ASi-3

The device communicates safely via the standard ASi-3 Safety and/or ASi-5 Safety.

ASi Safety

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input.

Inputs digital, EDM
Inputs safety, expandable to

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety outputs, independent according to SIL 3, expandable to Safety communication

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Article No.
BWU3981
EtherCAT ASi-5/ASi-3
Gateway with integrated ASi-5/ASi-3 Safety Monitor
ASi-3 compatible, ASi-5 compatible
ASi-3 Safety capable, ASi-5 Safety capable
no local safe inputs
no local input
max. 62 x 2 channels, max. 1922 in max. configuration
no local safe output
max. 64, max. 1984 in max. configuration
Safe Link
EtherCAT
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU3982
EtherCAT ASi-5/ASi-3
Gateway with integrated ASi-5/ASi-3 Safety Monitor
ASi-3 compatible, ASi-5 compatible
ASi-3 Safety capable, ASi-5 Safety capable
no local safe inputs
no local input
max. 62 x 2 channels, max. 1922 in max. configuration
no local safe output
max. 64, max. 1984 in max. configuration
Safe Link
EtherCAT
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU2281
Safety, EtherCAT
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
no Safety communication
EtherCAT
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
RS 232
yes
yes
no
IP20
BWU2338
Safety, EtherCAT
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
no Safety communication
EtherCAT
2 ASi networks, 1 ASi-3 Master
yes, max. 4 A/ASi network
RS 232
yes
yes
no
IP20
BWU3418
Safety, EtherCAT
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 64, max. 1984 in max. configuration
FSoE, Safe Link
EtherCAT
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU3509
Safety, EtherCAT
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 32, max. 992 in max. configuration
FSoE, Safe Link
EtherCAT
1 ASi network, 1 ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU2944
Safety, EtherCAT
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
EtherCAT
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU2797
Safety, EtherCAT
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
EtherCAT
1 ASi network, 1 ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20

Archive Safety Monitors, Safety POWERLINK

Figure Type Model

The device communicates via the standard ASi-3 and/or ASi-5.

ASi-5/ASi-3

The device communicates safely via the standard ASi-3 Safety and/or ASi-5 Safety.

ASi Safety

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input.

Inputs digital, EDM
Inputs safety, expandable to

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety outputs, independent according to SIL 3, expandable to Safety communication

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Article No.
BWU3828
Safety, POWERLINK ASi-5/ASi-3
Gateway with integrated Safety Monitor
ASi-3 compatible, ASi-5 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 64, max. 1984 in max. configuration
Safe Link
OPC UA, POWERLINK, REST API
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU3176
Safety, POWERLINK
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
POWERLINK
2 ASi networks, 2 ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20
BWU3177
Safety, POWERLINK
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
POWERLINK
1 ASi network, 1 ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20

Archive Safety Monitors, Safety CANopen

Figure Type Model

The device communicates via the standard ASi-3 and/or ASi-5.

ASi-5/ASi-3

The device communicates safely via the standard ASi-3 Safety and/or ASi-5 Safety.

ASi Safety

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input.

Inputs digital, EDM
Inputs safety, expandable to

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety outputs, independent according to SIL 3, expandable to Safety communication

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Article No.
BWU2804
Safety, CANopen
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
CANopen
1 ASi network, 1 ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20

Archive Safety Monitors, Safety CC-Link

Figure Type Model

The device communicates via the standard ASi-3 and/or ASi-5.

ASi-5/ASi-3

The device communicates safely via the standard ASi-3 Safety and/or ASi-5 Safety.

ASi Safety

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input.

Inputs digital, EDM
Inputs safety, expandable to

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety outputs, independent according to SIL 3, expandable to Safety communication

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Article No.
BWU2833
Safety, CC-Link
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
CC-Link
1 ASi network, 1 ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20

Archive Safety Monitors, Safety DeviceNet

Figure Type Model

The device communicates via the standard ASi-3 and/or ASi-5.

ASi-5/ASi-3

The device communicates safely via the standard ASi-3 Safety and/or ASi-5 Safety.

ASi Safety

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input.

Inputs digital, EDM
Inputs safety, expandable to

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety outputs, independent according to SIL 3, expandable to Safety communication

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Article No.
BWU2972
Safety, DeviceNet
Gateway with integrated Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
DeviceNet
1 ASi network, 1 ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic
yes
yes
optional
IP20

Archive Safety Monitors, Safety Monitor in Stainless Steel

Figure Type Model

The device communicates via the standard ASi-3 and/or ASi-5.

ASi-5/ASi-3

The device communicates safely via the standard ASi-3 Safety and/or ASi-5 Safety.

ASi Safety

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input.

Inputs digital, EDM
Inputs safety, expandable to

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety outputs, independent according to SIL 3, expandable to Safety communication

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Article No.
BWU2044
Safety Monitor in Stainless Steel
Safety Monitor in Stainless Steel
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
2
max. 62 x 2 channels
2 release circuits, 2 x 2 relay
no expandable safety outputs
no Safety communication
ASi monitors
1 ASi network, no ASi Master, ASi Monitor
no, max. 8 A/ASi network, redundant supply
RS 232
yes
yes
no
IP20
BWU2205
Safety Monitor in Stainless Steel
Safety Monitor in Stainless Steel
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
2 release circuits, 2 x 2 relay
max. 16
no Safety communication
ASi monitors
2 ASi networks, no ASi Master, ASi Monitor
no, max. 8 A/ASi network, redundant supply
Ethernet diagnostic
yes
yes
no
IP20
BWU2186
Safety Monitor in Stainless Steel
Safety Monitor in Stainless Steel
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
2 release circuits, 2 x 2 relay
max. 16
no Safety communication
ASi monitors
2 ASi networks, no ASi Master, ASi Monitor
no, max. 8 A/ASi network, redundant supply
RS 232
yes
yes
no
IP20
BWU2000
Safety Monitor in Stainless Steel
Safety Monitor in Stainless Steel
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
4
max. 62 x 2 channels
4 release circuits, 2 x relay, 2 x electronic safe outputs
max. 16
no Safety communication
ASi monitors
2 ASi networks, no ASi Master, ASi Monitor
no, max. 8 A/ASi network, redundant supply
RS 232
yes
yes
no
IP20

Archives Consortium Safety Monitor

Figure Type Model

The device communicates via the standard ASi-3 and/or ASi-5.

ASi-5/ASi-3

The device communicates safely via the standard ASi-3 Safety and/or ASi-5 Safety.

ASi Safety

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety

An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input.

Inputs digital, EDM
Inputs safety, expandable to

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety
Safety outputs, independent according to SIL 3, expandable to Safety communication

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Article No.
BW1765
Consortium Safety Monitor
Consortium Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
2
max. 31 x 2 channels
2 release circuits, 2 x 2 relay
no expandable safety outputs
no Safety communication
ASi monitors
1 ASi network, no ASi Master, ASi Monitor
no, max. 8 A/ASi network
RS 232
no
no
no
IP20
BW1764
Consortium Safety Monitor
Consortium Safety Monitor
ASi-3 compatible
ASi-3 Safety capable
no local safe inputs
2
max. 31 x 2 channels
1 release circuit, 1 x 2 relay
no expandable safety outputs
no Safety communication
ASi monitors
1 ASi network, no ASi Master, ASi Monitor
no, max. 8 A/ASi network
RS 232
no
no
no
IP20