Search
BWU4977 | ASi-5 Self-configuring I/O Module, IP54, M12, 16I/O
ASi-5 self-configuring I/O module in cable duct housing in IP54, with 8 x M12 cable sockets, straight, 5 poles, up to 16 digital inputs, up to 16 digital outputs, Y/mixed wiring, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, flat design, installation in cable duct possible…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
-
View this product in section Drive solutions
BWU4979 | ASi-5 Self-configuring I/O Module, IP54, M12, 8I/O
ASi-5 self-configuring I/O module in cable duct housing in IP54, with 4 x M12 cable sockets, straight, 5 poles, up to 8 digital inputs, up to 8 digital outputs, Y/mixed wiring, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, flat design, installation in cable duct possible…
BWU4740 | Active Distributor ASi Motor Module for Lenze Smart Motor, IP67, 4I/3O
Active Distributor ASi Motor Module, IP67, housing depth 35 mm, for 1 x Lenze Smart Motor, 4 digital inputs, 3 digital outputs, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 1 x M12 cable socket, straight, 5 poles, cable length 0,3 m, 1 x M12 cable…
BWU3604 | Active Distributor ASi Safety, IP54, 1SI/2O
Active Distributor ASi Safety, IP54, housing depth 35 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, 2 digital outputs, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 1 x round cable/connecting wires, cable length 2 m, flat…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3413 | Active Distributor ASi Safety, IP67, 1SI
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, input voltage/sensor supply out of ASi, periphery connection via 1 x M12 cable socket, angled, 5 poles, cable length 1 m, flat design, installation in cable duct possible (installation…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3553 | Active Distributor ASi Safety, IP67, 1SI
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, input voltage/sensor supply out of ASi, periphery connection via 1 x M8cable socket, straight, 4 poles, cable length 0,20 m, flat design, installation in cable duct possible…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3373 | Active Distributor ASi Safety, IP67, 1SI
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, input voltage/sensor supply out of ASi, periphery connection via 1 x round cable/connecting wires, cable length 0,3 m, flat design, installation in cable duct possible (installation…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3600 | Active Distributor ASi Safety, IP67, 1SI
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, input voltage/sensor supply out of ASi, periphery connection via 2 x round cables/connecting wires, cable length 10 m, flat design, installation in cable duct possible (installation depth…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3626 | Active Distributor ASi Safety, IP67, 1SI
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, input voltage/sensor supply out of ASi, periphery connection via 1 x M12 cable socket, straight, 5 poles, cable length 1 m, flat design, installation in cable duct possible (installation…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU4701 | Active Distributor ASi Safety, IP67, 1SI
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, input voltage/sensor supply out of ASi, periphery connection via 1 x M12 cable socket, straight, 5 poles, cable length 2 m, flat design, installation in cable duct possible (installation…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3488 | Active Distributor ASi Safety, IP67, 1SI/1I/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for OSSDs, 1 digital input, 1 digital output, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 1 x M12 cable socket, straight, 8 poles, cable length 1…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3565 | Active Distributor ASi Safety, IP67, 1SI/1I/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for OSSDs, 1 digital input, 1 digital output, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 1 x M12 cable socket, straight, 8 poles, cable length 1…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3635 | Active Distributor ASi Safety, IP67, 1SI/1I/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for OSSDs, 1 digital input, 1 digital output, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 1 x M12 cable socket, straight, 8 poles, cable length 1…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3638 | Active Distributor ASi Safety, IP67, 1SI/1I/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for OSSDs, 1 digital input, 1 digital output, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 1 x M12 cable socket, straight, 8 poles, cable length 1…
BWU3721 | Active Distributor ASi Safety, IP67, 1SI/1I/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for OSSDs, 1 digital input, 1 digital output, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 1 x M12 cable socket, straight, 8 poles, cable length 5…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3248 | Active Distributor ASi Safety, IP67, 1SI/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, 1 digital output, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 1 x round cable/connecting wires, cable length 1 m, flat…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3249 | Active Distributor ASi Safety, IP67, 1SI/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, 1 digital output, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 2 x round cables/connecting wires, cable length 1 m, flat…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3299 | Active Distributor ASi Safety, IP67, 1SI/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for OSSDs, 1 digital output, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 1 x M12 cable socket, angled, 5 poles, cable length 1 m, flat design,…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3376 | Active Distributor ASi Safety, IP67, 1SI/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for OSSDs, 1 digital output, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 1 x M12 cable socket, straight, 5 poles, cable length 1 m, flat design,…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3599 | Active Distributor ASi Safety, IP67, 1SI/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, 1 digital output, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 1 x round cable/connecting wires, cable length 10 m, flat…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3627 | Active Distributor ASi Safety, IP67, 1SI/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for OSSDs, 1 digital output, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 1 x M12 cable socket, straight, 5 poles, cable length 5 m, flat design,…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3425 | Active Distributor ASi Safety, IP67, 1SI/1O
Active Distributor ASi Safety, IP67, housing depth 35 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, 1 digital output, input voltage/sensor supply out of ASi, output voltage/actuator supply out of AUX, periphery connection via 1 x round cable/connecting wires, cable length 1 m, flat…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3796 | Active Distributor ASi Safety, IP67, 1SI/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, 1 digital output, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 1 x M12 cable socket, angled, 8 poles, cable length 1 m, flat…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU4702 | Active Distributor ASi Safety, IP67, 1SI/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, 1 digital output, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 1 x M12 cable socket, straight, 8 poles, cable length 1 m,…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU3718 | Active Distributor ASi Safety, IP67, 1SI/2O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for OSSDs, 2 digital outputs, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 1 x M12 cable socket, straight, 8 poles + 1 x M12 cable socket,…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules