Search
BW4211 | Small Starter Kit ASi-5/IO-Link via PROFINET
Small Starter Kit ASi-5/IO-Link via PROFINET, fully assembled and pre-wired in a practical case, will be assembled by default with an ASi-5 PROFINET Gateway in stainless steel and an ASi-5 Module with integrated IO-Link Master, other prevalent fieldbus systems are available on request.
-
View this product in section Gateways
-
View this product in section ASi Slaves/IO-Link Masters
-
View this product in section I/O Modules
BW4229 | Small Starter Kit ASi-5/IO-Link via EtherNet/IP
Small Starter Kit ASi-5/IO-Link via EtherNet/IP, fully assembled and pre-wired in a practical case, will be assembled by default with an ASi-5 EtherNet/IP Gateway in stainless steel and an ASi-5 Modul with integrated IO-Link Master, other prevalent fieldbus systems are available on request.
-
View this product in section Gateways
-
View this product in section ASi Slaves/IO-Link Masters
-
View this product in section I/O Modules
BWU3861 | ASi-5/ASi-3 safe Schneider drives over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters
ASi-5/ASi-3 safe Schneider drives over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters, REST API, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 62 x 2 channels…
-
View this product in section Safety Monitor
-
View this product in section Gateways
BWU3865 | ASi-5/ASi-3 openSAFETY via POWERLINK Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters
ASi-5/ASi-3 openSAFETY via POWERLINK Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters, REST API, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 62 x 2 channels safe inputs,…
-
View this product in section Safety Monitor
-
View this product in section Gateways
BWU3994 | ASi-5/ASi-3 openSAFETY over POWERLINK Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters
ASi-5/ASi-3 openSAFETY over POWERLINK Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master, OPC UA server, REST API, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, expandable to max. 31 x 2 channels safe inputs, 1891 x 2 channels safe inputs in max.…
BWU3996 | ASi-5/ASi-3 openSAFETY over POWERLINK Gateway with integrated Safety Monitor with coded clamps, 2 ASi-5/ASi-3 masters
ASi-5/ASi-3 openSAFETY over POWERLINK Gateway with integrated Safety Monitor with coded clamps, 2 ASi-5/ASi-3 masters, REST API, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 62 x 2…
BWU3858 | ASi-5/ASi-3 Safety over EtherCAT Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters
ASi-5/ASi-3 Safety over EtherCAT Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters, OPC UA server, REST API, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 62 x 2…
-
View this product in section Safety Monitor
-
View this product in section Gateways
BWU3583 | ASi-5/ASi-3 Safety over EtherCAT Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master
ASi-5/ASi-3 Safety over EtherCAT Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master, OPC UA server, REST API, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 31 x 2 channels…
-
View this product in section Safety Monitor
-
View this product in section Gateways
BWU3979 | ASi-5/ASi-3 Safety over EtherCAT Gateway with integrated ASi-5/ASi-3 Safety Monitor, 2 ASi-5/ASi-3 master
ASi-5/ASi-3 Safety over EtherCAT Gateway with integrated ASi-5/ASi-3 Safety Monitor, 2 ASi-5/ASi-3 master, OPC UA server, REST API, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, expandable to max. 62 x 2 channels safe inputs, 1922 x 2 channels safe inputs in max.…
BWU3980 | ASi-5/ASi-3 Safety over EtherCAT Gateway with integrated ASi-5/ASi-3 Safety Monitor, 1 ASi-5/ASi-3 master
ASi-5/ASi-3 Safety over EtherCAT Gateway with integrated ASi-5/ASi-3 Safety Monitor, 1 ASi-5/ASi-3 master, OPC UA server, REST API, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, expandable to max. 31 x 2 channels safe inputs, 1891 x 2 channels safe inputs in max.…
BWU3674 | ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters
ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters, OPC UA server, REST API, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 62 x 2 channels…
BWU3833 | ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 master
ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 master, OPC UA server, REST API, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, expandable to max. 62 x 2 channels safe inputs, 1922 x 2 channels safe inputs in max.…