PROFINET Fieldbus system
What is PROFINET?
PROFINET is an open Industrial Ethernet standard developed by Siemens and the PROFIBUS User Organization e.V. (PNO). PROFINET uses TCP/IP, is real-time capable, and allows devices from different manufacturers to communicate without any special interface adaptations. The concept behind PROFINET is a modular one, so that the user can decide which functionality to use. PROFINET is used to connect decentralized peripherals to a control system. The standard is used in the manufacturing industry, process industry, and logistics for the efficient control and monitoring of production processes.
PROFINET Gateways
PROFINET ASi Gateways
ASi-5/ASi-3 PROFINET gateways in stainless steel provide an interface for a PROFINET fieldbus. These certified ASi gateways are available in various versions with IP20 protection rating.
PROFINET ASi
Figure | Model | Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:
| The device communicates via the standard ASi-3 and/or ASi-5. | Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|
Gateway
|
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
yes
|
yes
|
optional
| BWU3852 ASi-5/ASi-3 PROFINET Gateway in stainless steel, 2 ASi-5/ASi-3 masters | |
Gateway
|
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 8 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
yes
|
yes
|
optional
| BWU4257 ASi-5/ASi-3 PROFINET Gateway in stainless steel, 2 ASi-5/ASi-3 masters | |
Gateway
|
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus
|
yes
|
yes
|
no
| BWU3847 24 Volt ASi-5/ASi-3 PROFINET Gateway in stainless steel, 1 ASi-5/ASi-3 master | |
Gateway
|
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 8 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
yes
|
yes
|
optional
| BWU3848 ASi-5/ASi-3 PROFINET Gateway in stainless steel, 1 ASi-5/ASi-3 master | |
Gateway
|
PROFINET
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus
|
yes
|
yes
|
no
| BWU3972 24 Volt ASi-5/ASi-3 PROFINET Gateway in stainless steel, 1 ASi-5/ASi-3 master | |
Gateway
|
PROFINET
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 8 A/ASi network
|
Ethernet fieldbus
|
yes
|
yes
|
optional
| BWU4818 ASi-5/ASi-3 PROFINET Gateway in stainless steel, 1 ASi-5/ASi-3 Master | |
Gateway
|
PROFINET
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus
|
yes
|
yes
|
optional
| BWU3363 ASi-3 PROFINET Gateway in Stainless Steel, 2 masters | |
Gateway
|
PROFINET
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 8 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
yes
|
yes
|
optional
| BWU4855 ASi-3 PROFINET Gateway in stainless steel, 2 ASi-3 Masters | |
Gateway
|
PROFINET
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus
|
yes
|
yes
|
optional
| BWU2919 24 Volt ASi-3 PROFINET Gateway in Stainless Steel, 1 master | |
Gateway
|
PROFINET
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
yes, max. 8 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
yes
|
yes
|
optional
| BWU5021 ASi-3 PROFINET Gateway in stainless steel, 1 ASi-3 master | |
Starter Kits
|
OPC UA, PROFINET
|
ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus
|
yes
|
yes
|
-
| BW4211 Small Starter Kit ASi-5/IO-Link via PROFINET |
Safety, PROFINET ASi Gateways
The certified ASi gateways with integrated safety monitor are available in different versions with protection class IP20. All gateways feature the Safe Link technology, which makes it possible to connect different system components easily and flexibly. Some product variants offer integrated PROFIsafe communication for easy integration of the safe signals into the F-CPU.
Safety, PROFINET ASi
Figure | Model | Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:
| The device communicates via the standard ASi-3 and/or ASi-5. | Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Safety communication | Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.
| Suitable for applications up to category 4/PLe/SIL 3. | Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
PROFIsafe (F-CPU), Safe Link
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
yes
|
yes
|
optional
| BWU3953 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated ASi-5/ASi-3 Safety Monitor, 2 ASi-5/ASi-3 masters, 6SI/6SO | |
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
OPC UA, PROFINET
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, optimized for 2 x NEC class 2 power supplies
|
Ethernet diagnostic, Ethernet fieldbus
|
PROFIsafe (F-CPU), Safe Link
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
yes
|
yes
|
optional
| BWU3830 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated ASi-5/ASi-3 safety monitor, 2 ASi-5/ASi-3 masters, 6SE/6SO | |
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
Safe Link
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
yes
|
yes
|
optional
| BWU3952 ASi-5/ASi-3 PROFINET Gateway with integrated ASi-5/ASi-3 Safety Monitor, 2 ASi-5/ASi-3 masters, 6SI/6SO | |
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
PROFIsafe (F-CPU), Safe Link
|
no local safe inputs
|
no local safe output
|
yes
|
yes
|
optional
| BWU3973 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated ASi-5/ASi-3 Safety Monitor, 2 ASi-5/ASi-3 master | |
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
PROFIsafe (F-CPU), Safe Link
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
yes
|
yes
|
optional
| BWU3954 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated ASi-5/ASi-3 Safety Monitor, 1 ASi-5/ASi-3 master, 6SI/6SO | |
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
Safe Link
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
yes
|
yes
|
optional
| BWU3955 ASi-5/ASi-3 PROFINET Gateway with integrated ASi-5/ASi-3 Safety Monitor, 1 ASi-5/ASi-3 master, 6SI/6SO | |
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
PROFIsafe (F-CPU), Safe Link
|
no local safe inputs
|
no local safe output
|
yes
|
yes
|
optional
| BWU3974 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated ASi-5/ASi-3 Safety Monitor, 1 ASi-5/ASi-3 master | |
Gateway with integrated Safety Monitor
|
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic, Ethernet fieldbus
|
Safe Link
|
no local safe inputs
|
no local safe output
|
yes
|
yes
|
optional
| BWU3998 ASi-5/ASi-3 PROFINET Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
GE Digital Achilles® Robustness Test (Level 1 and 2, Version No.
Ethernet fieldbus interface (PROFINET, EtherNet/IP) and Ethernet diagnostic interface of the ASi-5/ASi-3 gateways are submitted to strict robustness testing via the Achilles Test Software to ensure robustness against vulnerabilities to cyber attacks. The field update capabilities of the gateway enable continuous firmware and security updates to continuously improve the functionality and robustness of the device.
The PROFINET Master Simulator is an easy to use software for data exchange with PROFINET devices of many suppliers.
The PROFINET Master Simulator can exchange data with many PROFINET devices even without a PROFINET Master. Furthermore the PROFINET Master Simulator also processes GSD-files as well as the input of special configurations to start the data exchange with PROFINET devices. Identification, renaming and address assignment of PROFINET devices is also possible.
Furthermore, the data, in particular the diagnostic function can be displayed binary, hexadecimal and now also as ASCII code. Output data can be transmitted consistently.
In jog mode, it is possible to keep outputs active for exactly as long as the mouse button is pressed. The PROFINET Master Simulator Plus additionally supports PROFIsafe modules, a log function for I/O data, and the transmission of acyclic data (Record Data CR).
However as the PROFINET Master Simulator is a monitoring and commissioning tool for PROFINET devices, it is not designed to control automation processes.
PROFINET Master Simulator
Figure | Type | Safety fieldbus | Log function of I/O data | Sending of acyclic data | Article No. |
---|---|---|---|---|---|
PROFINET Master Simulator
|
no
|
no
|
no
| BW4938 PROFINET Master Simulator, One-Year License | |
PROFINET Master Simulator
|
PROFIsafe
|
yes
|
Read/write parameters acyclically
| BW4939 PROFINET Master Simulator Plus, One-Year License | |
PROFINET Master Simulator
|
PROFIsafe
|
yes
|
Read/write parameters acyclically
| BW5069 PROFINET Master Simulator Plus, DLL Kit, One-Year License |
1Fieldbus interface
Communication interface between fieldbus and gateway:
interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:
- PROFIBUS
- PROFINET
- EtherNet/IPTM + Modbus TCP
- BACnet/IP
- DeviceNet
- ControlLogix
- Compact-/MicroLogix
- EtherCat
- POWERLINK
- CC-Link
- CANopen
- RS 485 Modbus
- OPC UA server
2ASi-5/ASi-3
The device communicates via the standard ASi-3 and/or ASi-5.
3Number of ASi networks, number of ASi Master
Standard devices
"Single Master":
1 ASi network, 1 ASi-5/ASi-3 Master.
1 ASi network, 1 ASi-3 Master.
"Double Master":2 ASi networks, 2 ASi-5/ASi-3 Masters.
2 ASi networks, 2 ASi-3 Masters.
Safety devices
"Single Master" :
1 ASi network, 1 ASi-5/ASi-3 Master.
1 ASi network, 1 ASi-3 Master.
"Double Master" :2 ASi networks, 2 ASi-5/ASi-3 Masters.
2 ASi networks, 2 ASi-3 Masters.
"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.4Integrated decoupling, ASi current measurement in the gateway
" yes, max. 4 A/ASi network ":
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).
Operation with short cable lengths with standard 24 V power supply possible.
" yes, max. 8 A/ASi network ":Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).
Operation with short cable lengths with standard 24 V power supply possible.
"yes, optimized for 2 x NEC class 2 power supplies"Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
"no, max. 8 A/ASi network, redundant supply ":1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.
Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
" no, max. 8 A/ASi network ":1 ASi power supply per ASi network.
5Diagnostic and configuration interface
Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.
6Recognition of duplicate ASi addresses
Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.
7ASi fault detector
Checks the ASi line for interference effects such as noise, external voltages, ...
8Programming in C
Using a C-program offers the possibility to run mini-PLC functions with a gateway.
9Inputs Safety
Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.
Suitable for applications up to category 4/PLe/SIL 3.10Outputs Safety
Suitable for applications up to category 4/PLe/SIL 3.
2ASi-5/ASi-3
The device communicates via the standard ASi-3 and/or ASi-5.
3Number of ASi networks, number of ASi Master
Standard devices
"Single Master":
1 ASi network, 1 ASi-5/ASi-3 Master.
1 ASi network, 1 ASi-3 Master.
"Double Master":2 ASi networks, 2 ASi-5/ASi-3 Masters.
2 ASi networks, 2 ASi-3 Masters.
Safety devices
"Single Master" :
1 ASi network, 1 ASi-5/ASi-3 Master.
1 ASi network, 1 ASi-3 Master.
"Double Master" :2 ASi networks, 2 ASi-5/ASi-3 Masters.
2 ASi networks, 2 ASi-3 Masters.
"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.4Integrated decoupling, ASi current measurement in the gateway
" yes, max. 4 A/ASi network ":
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).
Operation with short cable lengths with standard 24 V power supply possible.
" yes, max. 8 A/ASi network ":Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).
Operation with short cable lengths with standard 24 V power supply possible.
"yes, optimized for 2 x NEC class 2 power supplies"Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
"no, max. 8 A/ASi network, redundant supply ":1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.
Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
" no, max. 8 A/ASi network ":1 ASi power supply per ASi network.
5Diagnostic and configuration interface
Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.
6Recognition of duplicate ASi addresses
Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.
7ASi fault detector
Checks the ASi line for interference effects such as noise, external voltages, ...
8Programming in C
Using a C-program offers the possibility to run mini-PLC functions with a gateway.
9Inputs Safety
Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.
Suitable for applications up to category 4/PLe/SIL 3.10Outputs Safety
Suitable for applications up to category 4/PLe/SIL 3.