BWU4393 | ASi-5 Safety Input Module, IP67, M12, 4SI/4I/O
ASi-5 Safety Input Module in IP67, with 4 x M12 sockets, up to 4 x 1 channel (SIL1, cat. 2, PLc) or up to 2 x 2 channels safe inputs (SIL 3, Cat. 4, PLe) for floating contacts, up to 4 digital inputs, up to 4 digital outputs, Y/mixed wiring, input voltage/sensor supply out of AUX, output…
BWU4277 | ASi-5 Safety I/O Module, IP20, 14SI/2SO
ASi-5 Safety I/O Module in IP20, 22,5 mm x 114 mm, with 6 x 4 contacts, up to 14 x 1 channel safe inputs (SIL1, cat. 2, PLc) or up to 7 x 2 channels safe inputs (SIL 3, cat. 4, PLe) for floating contacts, OSSDs, complementary switch, inputs SI13+SI14 optional as EDM inputs, up to 14 standard inputs, 2 release…
BWU4974 | Active Distributor ASi-5 Motor Module for Lenze i550 motec frequency inverter, IP67, 1M
Active distributor ASi-5 motor module, IP67, housing depth 35 mm, for 1 x Lenze i550 motec frequency inverter with Modbus TCP interface, periphery connection via 1 x M12 cable plug, D coded, straight, 4 poles, cable length 1 m, flat design, installation in cable duct possible (installation depth > 35…
BW5164 | Addressing aid for active distributors
Addressing aid for addressing of active distributors ASi-5 or ASi-3 using the address programming device Kit consisting of 1 x substructure module for active distributors 1 x ASi profile cable, to connecting wires, 1 m 1 x connection terminals for connection of ASi
BWU5129 | Active Distributor ASi Safety, IP67, 1SI/1O
Active Distributor ASi Safety, IP67, housing depth 35 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, 1 digital output, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 1 x M12 cable socket, angled, 8 poles, cable length 2 m, flat…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
BWU4276 | ASi-5 Counter Module, IP20, 4CI/8I/O
ASi-5 Counter Module in IP20, 22,5 mm x 114 mmm, with 6 x 4 contacts, up to 4 x counter inputs, pulse counter, range of value -2147483647 ... 2147483647 dec., counting rate max. 250 kHz, up to 8 digital inputs, up to 8 digital outputsinput voltage/sensor supply out of AUX, periphery connection via Push-in…
BW5153 | Safe coupling
Data exchange between ASi-5/ASi-3 gateways with different safety fieldbus protocols via Safe Link and the Ethernet diagnostic interface. "Safe coupling" functionality can be optionally activated for Safe Link.
BW5076 | Fieldbus coupling
Data exchange between ASi-5/ASi-3 gateways with different standard fieldbus protocols via the Ethernet diagnostic interface. "Fieldbus coupling" functionality can be optionally activated.
BWU3978 | ASi-5/ASi-3 CIP Safety™ over EtherNet/IP™ + ModbusTCP Gateway with integrated ASi-5/ASi-3 Safety Monitor, 2 ASi-5/ASi-3 masters
ASi-5/ASi-3 CIP Safety™ over EtherNet/IP™ + ModbusTCP Gateway with integrated ASi-5/ASi-3 Safety Monitor, 2 ASi-5/ASi-3 masters, OPC UA server, REST API, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, expandable to max. 62 x 2 channels safe inputs, 1922 x 2 channels…
-
View this product in section Safety Monitor
-
View this product in section Gateways
BWU3977 | ASi-5/ASi-3 CIP Safety™ over EtherNet/IP™ + ModbusTCP Gateway with integrated ASi-5/ASi-3 Safety Monitor, 1 ASi-5/ASi-3 master
ASi-5/ASi-3 CIP Safety™ over EtherNet/IP™ + ModbusTCP Gateway with integrated ASi-5/ASi-3 Safety Monitor, 1 ASi-5/ASi-3 master, OPC UA server, REST API, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, expandable to max. 62 x 2 channels safe inputs, 1922 x 2 channels…
-
View this product in section Safety Monitor
-
View this product in section Gateways
BWU5151 | Active distributor ASi Safety, IP67, 1SI/4O
Active distributor ASi Safety, IP67, housing depth 35 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, 4 digital outputs, input voltage/sensor supply out of ASi, output voltage/actuator supply out of AUX, periphery connection via 2 x round cables/connecting wires, cable length 1 m, flat…
How to configure digital I/Os as required and save resources in the process
How to configure digital I/Os as required and save resources in the process
Foundations ASi Safety at Work Bus systems ASi bus system PROFINET EtherNet/IP™ + Modbus/TCP EtherCAT POWERLINK Sercos PROFIBUS BACnet/IP DeviceNet ControlLogix CompactLogix/MicroLogix CC-Link CANopen PROFIsafe CIP Safety™ Safety over EtherCAT Optimal Implementation of Industry 4.0 Projects Using ASi-5 What…BWU4830 | ASi-5/ASi-3 EtherCAT Gateway in stainless steel, 2 ASi-5/ASi-3 Masters
ASi-5/ASi-3 EtherCAT gateway in stainless steel, 2 ASi-5/ASi-3 masters, OPC UA server, REST API, integrated decoupling, max. 8 A per ASi circuit, ASi current measurement in the gateway, diagnostic and configuration via Ethernet diagnostic interface, duplicate address recognition, ASi fault detector,…