Phoenix Contact

Product overview

In the following article overview you will find Bihl+Wiedemann products which can be used as replacement articles for Phoenix Contact products. Since Phoenix Contact no longer markets the products listed here themselves, you may source these replacement articles from us in the future.

Phoenix Contact, Overview of equivalent products: Master/Gateways

  • When using an equivalent Bihl+Wiedemann Gateway as a replacement for a Phoenix Contact Gateway, the device description file must be reinstalled.
  • The latest version of the device description file (GSD, EDS, XDD etc.) of the gateway is available in the "Downloads" section of the respective device.
Phoenix Contact Article No. Bihl+Wiedemann
Article No.
Figure
ASI MA PB XL AB - 2741710BWU1249
Bihl+Wiedemann Article No. BWU1249
FLX ASI MA 2PB EF - 2773607BWU1568
Bihl+Wiedemann Article No. BWU1568
FLX ASI MA PB SF - 2773597BWU1746
Bihl+Wiedemann Article No. BWU1746
ASI MA PC PCI - 2741257BW1195
Bihl+Wiedemann Article No. BW1195

 

 

Phoenix Contact, Overview of functionally equivalent products: Digital Modules ASi, IP67, M12

  • + Same number I/Os
  • + Same protection rating
  • ‒ Different dimensions/housing
  • ‒ Different node profile
  • ‒ Different required master profile
  • ‒ Different pin assignment
Phoenix Contact Article No. Manufacturer Type Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

Single wiring: 1 input or output per connection.

 

Y wiring: 2 inputs or outputs per connection.

 

Mixed wiring: 1 input and 1 output per connection.

 

Exact pin assignment see data sheet.
 

M8/M12 wiring
Connection

The node profiles allow numerous quickly configurable settings to be made on the module in order to optimally support the connected peripherals in most applications. The easiest way to select the node profiles is via the PC software.

If ID1 is in brackets (), this means it is the changeable default value; if ID1 is without brackets, it means it is a fixed, unchangeable value.

ASi node profile

Required profile that the ASi master needs to have in order to connect and operate the module.

Required Master profile

Bihl+Wiedemann offers modules with AB address, single address or ASi-5 address. In some cases, ASi modules can occupy several (different) addresses. Mixed operation of modules with different addressing in the same ASi circuit is permitted.
For ASi modules with two ASi-3 nodes, the second ASi-3 node is turned off as long as the first ASi-3 node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address

The connection to ASi and AUX (24 V auxiliary power) is made for modules in the active distributor or blue IP67 housing via the yellow or black ASi profile cable with piercing technology or via an M12 plug. Modules for the control cabinet are connected via terminals and PCB modules via wiring pins, connection wires or terminals.


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection
Bihl+Wiedemann
Article No.
Figure
FLX ASI 3.0 DIO 4/4 M12-2A - 2773474Phoenix Contact
IP67, 4 x M12
4
4 x electronic
out of ASi
out of AUX
Y
4 x M12 sockets, 5 poles
S-7.A.7.
M2 ... M4
1 AB address
ASi profile cable
BWU3144
Bihl+Wiedemann Article No. BWU3144
Bihl+Wiedemann
IP67, 8 x M12, EXTREME
4
4 x electronic
out of ASi
out of AUX
Y
8 x M12 sockets, 5 poles
S-7.A.7.7
M4
1 AB address
ASi profile cable
FLX ASI 3.0 DIO 4/4 M12-2A - 2773474Phoenix Contact
IP67, 4 x M12
4
4 x electronic
out of ASi
out of AUX
Y
4 x M12 sockets, 5 poles
S-7.A.7.
M2 ... M4
1 AB address
ASi profile cable
BWU2626
Bihl+Wiedemann Article No. BWU2626
Bihl+Wiedemann
IP67, 8 x M12
4
4 x electronic
out of ASi
out of AUX
Y
8 x M12 sockets, 5 poles
S-7.A.7.7
M4
1 AB address
ASi profile cable
FLX ASI DIO 4/3 M12-2A - 2773445Phoenix Contact
IP67, 4 x M12
4
3 x electronic
out of ASi
out of AUX
Y
4 x M12 sockets, 5 poles
S-7.A.7.2
M3 .. M4
1 AB address
ASi profile cable
BWU3375
Bihl+Wiedemann Article No. BWU3375
Bihl+Wiedemann
IP67, 4 x M12
4
3 x electronic
out of ASi
out of AUX
Y
4 x M12 sockets, 5 poles
S-7.A.(7).0
M3 .. M4
1 AB address
ASi profile cable
FLX ASI DIO 4/3 M12-2A - 2773445Phoenix Contact
IP67, 4 x M12
4
3 x electronic
out of ASi
out of AUX
Y
4 x M12 sockets, 5 poles
S-7.A.7.2
M3 .. M4
1 AB address
ASi profile cable
BWU3496
Bihl+Wiedemann Article No. BWU3496
Bihl+Wiedemann
IP67, 8 x M12
4
3 x electronic
out of ASi
out of AUX, 2 A per output
Single
8 x M12 sockets, 5 poles
S-7.A.(7).0
M3 .. M4
1 AB address
ASi profile cable
FLX ASI DIO 2/2 M12-2A - 2773432Phoenix Contact
IP67, 4 x M12
2
2 x electronic
out of ASi
out of AUX
Y
4 x M12 sockets, 5 poles
S-B.A.2.
M3 .. M4
1 AB address
ASi profile cable
BWU3456
Bihl+Wiedemann Article No. BWU3456
Bihl+Wiedemann
IP67, 4 x M12
2
2 x electronic
out of ASi
out of AUX
Y
4 x M12 sockets, 5 poles
S-7.A.7.7
M4
1 AB address
ASi profile cable
FLX ASI DIO 2/2 M12-2A - 2773432Phoenix Contact
IP67, 4 x M12
2
2 x electronic
out of ASi
out of AUX
Y
4 x M12 sockets, 5 poles
S-B.A.2.
M3 .. M4
1 AB address
ASi profile cable
BWU3141
Bihl+Wiedemann Article No. BWU3141
Bihl+Wiedemann
IP67, 4 x M12
2
2 x electronic
out of ASi
out of AUX
Single
4 x M12 sockets, 5 poles
S-7.A.7.7
M4
1 AB address
ASi profile cable

 

 

Phoenix Contact, Overview of functionally equivalent products: Digital Modules ASi, IP67, M8

  • + Same number I/Os
  • + Same protection rating
  • ‒ Different dimensions/housing
  • ‒ Different node profile
  • ‒ Different required master profile
  • ‒ Different pin assignment
Phoenix Contact Article No. Manufacturer Type Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

Single wiring: 1 input or output per connection.

 

Y wiring: 2 inputs or outputs per connection.

 

Mixed wiring: 1 input and 1 output per connection.

 

Exact pin assignment see data sheet.
 

M8/M12 wiring
Connection

The node profiles allow numerous quickly configurable settings to be made on the module in order to optimally support the connected peripherals in most applications. The easiest way to select the node profiles is via the PC software.

If ID1 is in brackets (), this means it is the changeable default value; if ID1 is without brackets, it means it is a fixed, unchangeable value.

ASi node profile

Required profile that the ASi master needs to have in order to connect and operate the module.

Required Master profile

Bihl+Wiedemann offers modules with AB address, single address or ASi-5 address. In some cases, ASi modules can occupy several (different) addresses. Mixed operation of modules with different addressing in the same ASi circuit is permitted.
For ASi modules with two ASi-3 nodes, the second ASi-3 node is turned off as long as the first ASi-3 node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address

The connection to ASi and AUX (24 V auxiliary power) is made for modules in the active distributor or blue IP67 housing via the yellow or black ASi profile cable with piercing technology or via an M12 plug. Modules for the control cabinet are connected via terminals and PCB modules via wiring pins, connection wires or terminals.


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection
Bihl+Wiedemann
Article No.
Figure
FLX ASI DIO 4/4 M8-1A - 2773416Phoenix Contact
IP67, 8 x M8
4
4 x electronic
out of ASi
out of AUX
Single
8 x M8 sockets, 3 poles
S-7.0.
M2 ... M4
1 Single address
ASi via M12
BW3661
Bihl+Wiedemann Article No. BW3661
Bihl+Wiedemann
IP67, 8 x M8
4
4 x electronic
out of ASi
out of AUX
Single
8 x M8 sockets, 3 poles
S-7.A.(7).0
M4
1 AB address
ASi profile cable
FLX ASI DIO 4/4 M8-1A - 2773416Phoenix Contact
IP67, 8 x M8
4
4 x electronic
out of ASi
out of AUX
Single
8 x M8 sockets, 3 poles
S-7.0.
M2 ... M4
1 Single address
ASi via M12
BWU2645
Bihl+Wiedemann Article No. BWU2645
Bihl+Wiedemann
IP67, 8 x M12
4
4 x electronic
out of AUX
out of AUX
Single
8 x M12 sockets, 5 poles
S-7.A.7.7
M4
1 AB address
ASi via M12
FLX ASI DIO 4/4 M8-1A - 2773416Phoenix Contact
IP67, 8 x M8
4
4 x electronic
out of ASi
out of AUX
Single
8 x M8 sockets, 3 poles
S-7.0.
M2 ... M4
1 Single address
ASi via M12
BWU2684
Bihl+Wiedemann Article No. BWU2684
Bihl+Wiedemann
IP67, 8 x M12
4
4 x electronic
out of ASi
out of AUX
Single
8 x M12 sockets, 5 poles
S-7.0.(F).E
M0 ... M4
1 Single address
ASi profile cable
FLX ASI DI 4 M8 - 2773403Phoenix Contact
IP67, 8 x M8
4
-
out of ASi
-
Single
8 x M8 sockets, 3 poles
S-0.0.
M2 ... M4
1 Single address
ASi via M12
BWU2620
Bihl+Wiedemann Article No. BWU2620
Bihl+Wiedemann
IP67, 4 x M12
4
no digital outputs
out of ASi
no output voltage
Single
4 x M12 sockets, 5 poles
S-0.A.(7).E
M3 .. M4
1 AB address
ASi profile cable
FLX ASI DI 4 M8 - 2773403Phoenix Contact
IP67, 8 x M8
4
-
out of ASi
-
Single
8 x M8 sockets, 3 poles
S-0.0.
M2 ... M4
1 Single address
ASi via M12
BW3661
Bihl+Wiedemann Article No. BW3661
Bihl+Wiedemann
IP67, 8 x M8
4
4 x electronic
out of ASi
out of AUX
Single
8 x M8 sockets, 3 poles
S-7.A.(7).0
M4
1 AB address
ASi profile cable
FLX ASI DI 4 M8 - 2773403Phoenix Contact
IP67, 8 x M8
4
-
out of ASi
-
Single
8 x M8 sockets, 3 poles
S-0.0.
M2 ... M4
1 Single address
ASi via M12
BW3521
Bihl+Wiedemann Article No. BW3521
Bihl+Wiedemann
IP67, 8 x M8
8
no digital outputs
out of ASi
no output voltage
Single
8 x M8 sockets, 3 poles
S1-0.A.(7).E, S2-0.A.(6).E
M3 .. M4
2 AB addresses
ASi profile cable
FLX ASI DI 4 M8 - 2773403Phoenix Contact
IP67, 8 x M8
4
-
out of ASi
-
Single
8 x M8 sockets, 3 poles
S-0.0.
M2 ... M4
1 Single address
ASi via M12
BWU3457
Bihl+Wiedemann Article No. BWU3457
Bihl+Wiedemann
IP67, 4 x M12
4
no digital outputs
out of ASi
no output voltage
Single
4 x M12 sockets, 5 poles
S-0.A.(7).E
M3 .. M4
1 AB address
ASi via M12

 

 

Phoenix Contact, Overview of functionally equivalent products: Digital Modules ASi, IP20

  • + Same number I/Os
  • + Same protection rating
  • + Same dimensions/housing
  • + Same node profile
  • + Same required master profile
  • ‒ Different terminal assignment
Phoenix Contact Article No. Manufacturer Type Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)
Connection

The node profiles allow numerous quickly configurable settings to be made on the module in order to optimally support the connected peripherals in most applications. The easiest way to select the node profiles is via the PC software.

If ID1 is in brackets (), this means it is the changeable default value; if ID1 is without brackets, it means it is a fixed, unchangeable value.

ASi node profile

Required profile that the ASi master needs to have in order to connect and operate the module.

Required Master profile

Bihl+Wiedemann offers modules with AB address, single address or ASi-5 address. In some cases, ASi modules can occupy several (different) addresses. Mixed operation of modules with different addressing in the same ASi circuit is permitted.
For ASi modules with two ASi-3 nodes, the second ASi-3 node is turned off as long as the first ASi-3 node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address

The connection to ASi and AUX (24 V auxiliary power) is made for modules in the active distributor or blue IP67 housing via the yellow or black ASi profile cable with piercing technology or via an M12 plug. Modules for the control cabinet are connected via terminals and PCB modules via wiring pins, connection wires or terminals.


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection
Bihl+Wiedemann
Article No.
Figure
ASI IO SV DIO 4/3 ABPhoenix Contact
IP20, 22,5 mm x 92 mm, 4 x 4 contacts
4
3 x electronic
out of AUX
out of AUX
push in terminals
S-7.A.(7).E
M3 .. M4
1 AB address
Push-in terminals
BWU4183
Bihl+Wiedemann Article No. BWU4183
Bihl+Wiedemann
IP20, 22,5 mm x 92 mm, 4 x 4 contacts
4
3 x electronic
out of AUX
out of AUX
push in terminals
S-7.A.(7).E
M3 .. M4
1 AB address
Push-in terminals

 

 

Phoenix Contact, Overview of functionally equivalent products: Digital Modules ASi, IP20

  • + Same number I/Os
  • + Same protection rating
  • ‒ Different dimensions/housing
  • ‒ Different node profile
  • ‒ Different required master profile
  • ‒ Different terminal assignment
Phoenix Contact Article No. Manufacturer Type Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)
Connection

The node profiles allow numerous quickly configurable settings to be made on the module in order to optimally support the connected peripherals in most applications. The easiest way to select the node profiles is via the PC software.

If ID1 is in brackets (), this means it is the changeable default value; if ID1 is without brackets, it means it is a fixed, unchangeable value.

ASi node profile

Required profile that the ASi master needs to have in order to connect and operate the module.

Required Master profile

Bihl+Wiedemann offers modules with AB address, single address or ASi-5 address. In some cases, ASi modules can occupy several (different) addresses. Mixed operation of modules with different addressing in the same ASi circuit is permitted.
For ASi modules with two ASi-3 nodes, the second ASi-3 node is turned off as long as the first ASi-3 node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address

The connection to ASi and AUX (24 V auxiliary power) is made for modules in the active distributor or blue IP67 housing via the yellow or black ASi profile cable with piercing technology or via an M12 plug. Modules for the control cabinet are connected via terminals and PCB modules via wiring pins, connection wires or terminals.


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection
Bihl+Wiedemann
Article No.
Figure
ASI IO ME DI 4 AB - 2741671Phoenix Contact
IP20, 25 mm x 105 mm, 6 x 4 contacts
4
-
selectable, out of ASi or out of AUX, Default out of ASi
-
push in terminals
S-0.A.0.
M4
1 AB address
Push-in terminals
BWU3265
Bihl+Wiedemann Article No. BWU3265
Bihl+Wiedemann
IP20, 22,5 mm x 114 mm, 4 x 4 contacts
4
no digital outputs
out of ASi
no output voltage
push in terminals
S-7.A.(7).E
M3 .. M4
1 AB address
Push-in terminals
ASI IO ME DI 4 AB - 2741671Phoenix Contact
IP20, 25 mm x 105 mm, 6 x 4 contacts
4
-
selectable, out of ASi or out of AUX, Default out of ASi
-
push in terminals
S-0.A.0.
M4
1 AB address
Push-in terminals
BWU3266
Bihl+Wiedemann Article No. BWU3266
Bihl+Wiedemann
IP20, 22,5 mm x 114 mm, 4 x 4 contacts
4
no digital outputs
out of AUX
no output voltage
push in terminals
S-7.A.(7).E
M3 .. M4
1 AB address
Push-in terminals

 

 

Phoenix Contact, Overview of functionally equivalent products: Power Supply

  • ‒ No earth fault and EMC monitor integrated in the power supply, all current Bihl + Wiedemann gateways have an integrated earth fault and EMC monitor
Phoenix Contact Article No. Manufacturer

"ASi power supply":

Special power supplies with integrated data decoupling unit for use in ASi-3 only networks. Suitable for all Bihl+Wiedemann ASi-3 gateways and safety monitors.

"30 V power supply":

Inexpensive standard power supplies, suitable as an alternative for use with ASi gateways and safety monitors with integrated data decoupling unit (version "1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 Volt ASi gateways.


30 V power supply, optimized for ASi-5/ASi-3:

Inexpensive standard power supplies, optimized for use with ASi-5/ASi-3 gateways and safety monitors with integrated data decoupling unit (version "1 power supply , 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 Volt ASi-5/ASi-3 gateways. In order to avoid interferences in ASi-5 communication, Bihl+Wiedemann recommends the use of power supplies optimized for ASi-5/ASi-3.


30 V power supply, optimized for ASi-5/ASi-3, NEC class 2 :

The 30 V/3 A power supply is UL certified, has power limitation <100 W and is designed for use in NEC class 2 networks. It is suitable for applications with 1 power supply per ASi network. In the case of power intensive applications, Bihl+Wiedemann recommends the use of a 30 V power supply without 100 W power limitation in combination with a power limitation module (BWU4189) for each ASi network.The power supply is optimized for use with ASi-5/ASi-3 gateways and safety monitors with integrated decoupling coils (version "1 power supplies, 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 V ASi-5/ASi-3 gateways. In order to avoid interferences in ASi-5 communication, Bihl+Wiedemann recommends the use of power supplies optimized for ASi-5/ASi-3.


"ASi power supply decoupling unit":

Supply of 2 ASi networks out of 1 power supply. Applicable with double masters without integrated data decoupling.


"Power decoupling unit":

Take up to 1,2 A out of ASi. In combination with an ASi Repeater: decouples 1,2 A from ASi Segment B and supplies Segment A with 1,2 A.

Power supply
Input voltage Output current

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Bihl+Wiedemann
Article No.
Figure
ASI QUINT 100-240/4.8 EFD - 2736699Phoenix Contact
ASi power supply
100 ... 240 VAC, 1 phase
4,8 A
IP20
BW1649
Bihl+Wiedemann Article No. BW1649
Bihl+Wiedemann
ASi power supply
90 ... 265 VAC, wide range supply
4 A
IP20

 

 

Phoenix Contact, Overview of equivalent products: Diagnostics/Commissioning

  • ASi Address Programming Device
  • Accessories for ASi Address Programming Device
  • Master Simulators
Phoenix Contact Article No. Bihl+Wiedemann
Article No.
Figure
ASI CC ADR - 2741338BW1191
Bihl+Wiedemann Article No. BW1191
ASI CC ADR CAB CINCH - 2741341BW1802
Bihl+Wiedemann Article No. BW1802
PB ECO LINK - 2741480BW1131
Bihl+Wiedemann Article No. BW1131

 

 

Phoenix Contact, Overview of equivalent products: Software

Phoenix Contact Article No. Bihl+Wiedemann
Article No.
Figure
AS-i Control ToolBW1203
Bihl+Wiedemann Article No. BW1203