Sercos Fieldbus system

What is Sercos?

Sercos (Serial real-time communication system) is an open, manufacturer-independent fieldbus standard that is used in industrial automation. As an IEC-standardized open interface, Sercos enables serial high-speed real-time communication without special interface adaptations – e.g. between industrial controllers, motion devices, inputs and outputs, other peripheral devices and standard Ethernet nodes. Sercos is often used in demanding applications with high requirements for dynamics and precision.

Sercos Gateways

Safety, Sercos ASi Gateways

The certified ASi Sercos Gateways with integrated safety monitor provide an interface for a Sercos fieldbus. These ASi gateways are available in various versions with IP20 protection rating. All gateways feature Safe Link technology, which makes it possible to connect different parts of the system easily and flexibly. They all also have an Ethernet diagnostic interface for convenient diagnostics. They also include an OPC UA server, which can be used to transfer all process data and additional information to the IT world.

Safety, Sercos ASi

Figure Model

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IPTM + Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface 1

The device communicates via the standard ASi-3 and/or ASi-5.

ASi-5/ASi-3 2
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master 3

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway 4

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface 5
Safety communication

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


Suitable for applications up to category 4/PLe/SIL 3.

Inputs Safety 6

Suitable for applications up to category 4/PLe/SIL 3.

Outputs Safety 7

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses 8

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector 9

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C 10
Article No.
BWU3861
Gateway with integrated Safety Monitor
OPC UA, REST API, Sercos
ASi-3 compatible, ASi-5 compatible
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
Safe Link, safe Schneider drives over Sercos
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
yes
yes
optional
Gateway with integrated Safety Monitor
OPC UA, REST API, Sercos
ASi-3 compatible, ASi-5 compatible
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
CIP Safety over Sercos, Safe Link
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
yes
yes
optional
BWU3845
Gateway with integrated Safety Monitor
OPC UA, REST API, Sercos
ASi-3 compatible, ASi-5 compatible
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
CIP Safety over Sercos, Safe Link
no local safe inputs
no local safe output
yes
yes
optional

 

 

Do you have questions about our products and solutions?

We would be happy to assist you.

  • 1Fieldbus interface

    Communication interface between fieldbus and gateway:

    interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

     

    • PROFIBUS
    • PROFINET
    • EtherNet/IPTM + Modbus TCP
    • BACnet/IP
    • DeviceNet
    • ControlLogix
    • Compact-/MicroLogix
    • EtherCat
    • POWERLINK
    • CC-Link
    • CANopen
    • RS 485 Modbus
    • OPC UA server
    • 2ASi-5/ASi-3

      The device communicates via the standard ASi-3 and/or ASi-5.

    • 3Number of ASi networks, number of ASi Master
      Standard devices

      "Single Master":

      1 ASi network, 1 ASi-5/ASi-3 Master.

      1 ASi network, 1 ASi-3 Master.

      "Double Master":

      2 ASi networks, 2 ASi-5/ASi-3 Masters.

      2 ASi networks, 2 ASi-3 Masters.

      Safety devices

      "Single Master" :

      1 ASi network, 1 ASi-5/ASi-3 Master.

      1 ASi network, 1 ASi-3 Master.

      "Double Master" :

      2 ASi networks, 2 ASi-5/ASi-3 Masters.

      2 ASi networks, 2 ASi-3 Masters.

      "Optional ASi Safety coupling circuit" :
      2 ASi networks, 1 ASi-3 Master.

    • 4Integrated decoupling, ASi current measurement in the gateway

      " yes, max. 4 A/ASi network ":

      Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

      Operation with short cable lengths with standard 24 V power supply possible.


      " yes, max. 8 A/ASi network ":

      Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

      Operation with short cable lengths with standard 24 V power supply possible.


      "yes, optimized for 2 x NEC class 2 power supplies"

      Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


      "no, max. 8 A/ASi network, redundant supply ":

      1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

      Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


      " no, max. 8 A/ASi network ":

      1 ASi power supply per ASi network.

    • 5Diagnostic and configuration interface

      Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

       

      The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

    • 6Inputs Safety

      Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


      Suitable for applications up to category 4/PLe/SIL 3.

    • 7Outputs Safety

      Suitable for applications up to category 4/PLe/SIL 3.

    • 8Recognition of duplicate ASi addresses

      Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

    • 9ASi fault detector

      Checks the ASi line for interference effects such as noise, external voltages, ...

    • 10Programming in C

      Using a C-program offers the possibility to run mini-PLC functions with a gateway.

     

  • 2ASi-5/ASi-3

    The device communicates via the standard ASi-3 and/or ASi-5.

  • 3Number of ASi networks, number of ASi Master
    Standard devices

    "Single Master":

    1 ASi network, 1 ASi-5/ASi-3 Master.

    1 ASi network, 1 ASi-3 Master.

    "Double Master":

    2 ASi networks, 2 ASi-5/ASi-3 Masters.

    2 ASi networks, 2 ASi-3 Masters.

    Safety devices

    "Single Master" :

    1 ASi network, 1 ASi-5/ASi-3 Master.

    1 ASi network, 1 ASi-3 Master.

    "Double Master" :

    2 ASi networks, 2 ASi-5/ASi-3 Masters.

    2 ASi networks, 2 ASi-3 Masters.

    "Optional ASi Safety coupling circuit" :
    2 ASi networks, 1 ASi-3 Master.

  • 4Integrated decoupling, ASi current measurement in the gateway

    " yes, max. 4 A/ASi network ":

    Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

    Operation with short cable lengths with standard 24 V power supply possible.


    " yes, max. 8 A/ASi network ":

    Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

    Operation with short cable lengths with standard 24 V power supply possible.


    "yes, optimized for 2 x NEC class 2 power supplies"

    Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


    "no, max. 8 A/ASi network, redundant supply ":

    1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

    Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


    " no, max. 8 A/ASi network ":

    1 ASi power supply per ASi network.

  • 5Diagnostic and configuration interface

    Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

     

    The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

  • 6Inputs Safety

    Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.


    Suitable for applications up to category 4/PLe/SIL 3.

  • 7Outputs Safety

    Suitable for applications up to category 4/PLe/SIL 3.

  • 8Recognition of duplicate ASi addresses

    Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

  • 9ASi fault detector

    Checks the ASi line for interference effects such as noise, external voltages, ...

  • 10Programming in C

    Using a C-program offers the possibility to run mini-PLC functions with a gateway.