Safety Monitor

The Safety Monitor enables safe transmission and processing of safety relevant data from safety input modules and safe shut-off of safety output modules remotely over ASi right where the potentially hazardous motion takes place. And always PLe compliant.
Bihl+Wiedemann offers the Safety Monitor for ASi Safety at Work as a stand-alone device for expanding existing ASi circuits with safety modules. For new systems we can provide our ASi-3 resp. ASi-5/ASi-3 gateways with integrated Safety Monitor and interfaces for the most commonly used automation systems using the most efficient method for safely constructing 1 or 2 ASi circuits at the same time. Even large applications with up to 1922 safety I/Os can be implemented with these devices using our “Safe Link over Ethernet” technology by connecting multiple gateways safely over Ethernet/Profinet.
For small applications with three or more safe signals you should consider our Safety Basic Monitor, a compact safety controller without gateway but with configurable status outputs. The module allows for universal expansion and is also ideal as a head station for special safety applications.

The Safety Monitor enables safe transmission and processing of safety relevant data from safety input modules and safe shut-off of safety output modules remotely over ASi right where the potentially hazardous motion takes place. And always PLe compliant.
Bihl+Wiedemann offers the Safety Monitor for ASi Safety at Work as a stand-alone device for expanding existing ASi circuits with safety modules. For new systems we can provide our ASi-3 resp. ASi-5/ASi-3 gateways with integrated Safety Monitor and interfaces for the most commonly used automation systems using the most efficient method for safely constructing 1 or 2 ASi circuits at the same time. Even large applications with up to 1922 safety I/Os can be implemented with these devices using our “Safe Link over Ethernet” technology by connecting multiple gateways safely over Ethernet/Profinet.
For small applications with three or more safe signals you should consider our Safety Basic Monitor, a compact safety controller without gateway but with configurable status outputs. The module allows for universal expansion and is also ideal as a head station for special safety applications.
Figure |
Fieldbus interface
|
Safety communication
|
Model
|
Inputs Safety
|
Outputs Safety
|
Number of ASi networks, number of ASi Master
|
Integrated decoupling, ASi current measurement in the gateway
| |
---|---|---|---|---|---|---|---|---|
OPC UA, PROFINET, REST API
|
PROFIsafe (F-CPU), Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
| ||
OPC UA, PROFINET, REST API
|
PROFIsafe (F-CPU), Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, optimized for 2 x NEC class 2 power supplies
| ||
OPC UA, PROFINET, REST API
|
Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
| ||
OPC UA, PROFINET, REST API
|
PROFIsafe (F-CPU), Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
no local safe inputs
|
no local safe output
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
| ||
OPC UA, PROFINET, REST API
|
PROFIsafe (F-CPU), Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
| ||
OPC UA, PROFINET, REST API
|
Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
| ||
OPC UA, PROFINET, REST API
|
PROFIsafe (F-CPU), Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
no local safe inputs
|
no local safe output
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
CIP Safety over EtherNet/IP, Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
CIP Safety over EtherNet/IP, Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
no local safe inputs
|
no local safe output
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
CIP Safety over EtherNet/IP, Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
CIP Safety over EtherNet/IP, Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
no local safe inputs
|
no local safe output
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, optimized for 2 x NEC class 2 power supplies
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
| ||
EtherCAT, OPC UA, REST API
|
FSoE, Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
3 x 2 channels, 6 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
| ||
EtherCAT, OPC UA, REST API
|
FSoE, Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
| ||
EtherCAT, OPC UA, REST API
|
Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
| ||
EtherCAT, OPC UA, REST API
|
Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
| ||
EtherCAT, OPC UA, REST API
|
FSoE, Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
no local safe inputs
|
no local safe output
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
| ||
EtherCAT, OPC UA, REST API
|
FSoE, Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
no local safe inputs
|
no local safe output
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
| ||
POWERLINK
|
Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
| ||
POWERLINK
|
Safe Link
|
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|