Gateways
With the ASi gateways from Bihl+Wiedemann you can transmit digital and analog data which have been read remotely through ASi modules to the host controller and set the output signals from the host controller to the actuators over the respective bus system.
Our gateways communicate according to the ASi-3 resp. ASi-5 standard and therefore ensure optimal exchange of the data. They are simple and quick to install and commission. The user benefits from the variety of standard implemented diagnostics functions such as duplicate address detection, earth fault and EMC monitoring as well as an optional PLC functionality.
Double Masters in one gateway are an especially cost-efficient approach. This allows two ASi circuits to be controlled by one gateway. The “Integrated decoupling, ASi current” version also requires just one power supply for both ASi circuits.
With the ASi gateways from Bihl+Wiedemann you can transmit digital and analog data which have been read remotely through ASi modules to the host controller and set the output signals from the host controller to the actuators over the respective bus system.
Our gateways communicate according to the ASi-3 resp. ASi-5 standard and therefore ensure optimal exchange of the data. They are simple and quick to install and commission. The user benefits from the variety of standard implemented diagnostics functions such as duplicate address detection, earth fault and EMC monitoring as well as an optional PLC functionality.
Double Masters in one gateway are an especially cost-efficient approach. This allows two ASi circuits to be controlled by one gateway. The “Integrated decoupling, ASi current” version also requires just one power supply for both ASi circuits.
Figure |
Fieldbus interface
|
ASi-5/ASi-3
|
Number of ASi networks, number of ASi Master
|
Integrated decoupling, ASi current measurement in the gateway
|
Inputs Safety
|
Outputs Safety
|
Safety communication
| |
---|---|---|---|---|---|---|---|---|
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
PROFINET
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
PROFINET
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
PROFINET
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
PROFINET
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
PROFINET
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
PROFINET
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
yes, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
yes, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherNet/IP, Modbus/TCP, OPC UA
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
no, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherCAT, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherCAT, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherCAT, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherCAT, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherCAT
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherCAT
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
no, max. 8 A/ASi network, redundant supply
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherCAT
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherCAT
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
no, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
BACnet/IP, OPC UA, REST API
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
BACnet/IP, OPC UA, REST API
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
no, max. 8 A/ASi network, redundant supply
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
OPC UA, POWERLINK, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
POWERLINK
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
POWERLINK
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
no, max. 8 A/ASi network, redundant supply
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
PROFIBUS
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
PROFIBUS
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
no, max. 8 A/ASi network, redundant supply
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
PROFIBUS
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
PROFIBUS
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
no, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
PROFIBUS
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
no, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
complete set CompactLogix, MicroLogix1500
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
no, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
CompactLogix, MicroLogix1500
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
no, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
complete set ControlLogix
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
no, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
ControlLogix
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
no, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
CANopen
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
CANopen
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
no, max. 8 A/ASi network, redundant supply
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
CANopen
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
no, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
CC-Link
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
DeviceNet
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
DeviceNet
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
no, max. 8 A/ASi network, redundant supply
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
DeviceNet
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
no, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
Modbus/RTU; RS 485
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
Modbus/RTU; RS 485
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
no, max. 8 A/ASi network, redundant supply
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
Modbus/RTU; RS 485
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
no, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
RS 232
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
no, max. 8 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
PROFIsafe (F-CPU), Safe Link
| ||
OPC UA, PROFINET
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, optimized for 2 x NEC class 2 power supplies
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
PROFIsafe (F-CPU), Safe Link
| ||
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| ||
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
PROFIsafe (F-CPU), Safe Link
| ||
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
PROFIsafe (F-CPU), Safe Link
| ||
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| ||
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
PROFIsafe (F-CPU), Safe Link
| ||
OPC UA, PROFINET, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
Safe Link
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
CIP Safety over EtherNet/IP, Safe Link
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
CIP Safety over EtherNet/IP, Safe Link
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
CIP Safety over EtherNet/IP, Safe Link
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
CIP Safety over EtherNet/IP, Safe Link
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
CIP Safety over EtherNet/IP, Safe Link
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, optimized for 2 x NEC class 2 power supplies
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| ||
EtherNet/IP, Modbus/TCP, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| ||
EtherCAT, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 4 A/ASi network
|
3 x 2 channels, 6 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
FSoE, Safe Link
| ||
EtherCAT, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
3 x 2 channels, 6 x 1 channel
|
6 release circuits, 6 x electronic safe outputs
|
FSoE, Safe Link
| ||
EtherCAT, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
FSoE, Safe Link
| ||
EtherCAT, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
FSoE, Safe Link
| ||
EtherCAT, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| ||
EtherCAT, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
FSoE, Safe Link
| ||
EtherCAT, OPC UA, REST API
|
ASi-3 compatible, ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
FSoE, Safe Link
| ||
BACnet/IP, OPC UA, REST API
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 8 A/ASi network
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| ||
BACnet/IP, OPC UA, REST API
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
no, max. 8 A/ASi network, redundant supply
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| ||
OPC UA, POWERLINK, REST API
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link, openSAFETY over POWERLINK
| ||
OPC UA, REST API, Sercos
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link, safe Schneider drives over Sercos
| ||
OPC UA, REST API, Sercos
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
CIP Safety over Sercos, Safe Link
| ||
OPC UA, REST API, Sercos
|
ASi-3 compatible, ASi-5 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
CIP Safety over Sercos, Safe Link
| ||
PROFIBUS
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 4 A/ASi network
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| ||
PROFIBUS
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
yes, max. 4 A/ASi network
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| ||
PROFIBUS
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
yes, max. 4 A/ASi network
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
PROFIsafe (F-CPU)
| ||
OPC UA, PROFINET
|
ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
| ||
EtherNet/IP, Modbus/TCP, OPC UA
|
ASi-5 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
no local safe inputs
|
no local safe output
|
no Safety communication
|