BWU305024 Volt ASi-3 EtherNet/IP + Modbus TCP Gateway in Stainless Steel, 1 master
There is a successor to this article → BWU3849
The successor is not recommended for use as a spare part - Conditions for selecting and using the successor
Product description
24 Volt ASi-3 EtherNet/IP + Modbus TCP Gateway in Stainless Steel, 1 ASi master, 1 power supply for 2 ASi networks, diagnostic and configuration via Ethernet/IP + Modbus TCP, duplicate address recognition, ASi fault detector
Technical data
Fieldbus interface
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:
| EtherNet/IP, Modbus/TCP |
ASi-5/ASi-3
The device communicates via the standard ASi-3 and/or ASi-5. | ASi-3 compatible |
Number of ASi networks, number of ASi Master
Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | 1 ASi network, 1 ASi-3 Master |
Integrated decoupling, ASi current measurement in the gateway
" yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | yes, max. 4 A/ASi network |
Inputs Safety
Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.
| no local safe inputs |
Outputs Safety
Suitable for applications up to category 4/PLe/SIL 3. | no local safe output |
Safety communication | no Safety communication |
How to get started with Bihl+Wiedemann products
How to easily implement your ASi installation
How to troubleshoot an existing ASi installation
Manuals
EPLAN Macros
Device Description Files (GSD, EDS, ESI, SDD, etc.)
Video Tutorial
- Video Tutorial: Tips & Tricks: Replacing a defective device (DE)
- Video Tutorial: Tips & Tricks: Replacing a defective device (EN)
- Video Tutorial: Tips & Tricks: Replacing a Gateway Using the Chip Card (DE)
- Video Tutorial: Tips & Tricks: Replacing a Gateway Using the Chip Card (EN)
- Video Tutorial: ASi Control Tools360: First Steps (DE)
- Video Tutorial: ASi Control Tools360: First Steps (EN)
- Video Tutorial: How to connect an Ethernet/IP Gateway to a Schneider PLC (DE)
Quick Start Guides
- Quick Start Guide: Tips & Tricks: Replacing a defective device (DE)
- Quick Start Guide: Tips & Tricks: Replacing a defective device (EN)
- Quick Start Guide: Rockwell RSLogix 5000 Version 20.00 and higher (DE)
- Quick Start Guide: Rockwell RSLogix 5000 Version 20.00 and higher (EN)
- Quick Start Guide: ASi Control Tools360 – First steps (DE)
- Quick Start Guide: ASi Control Tools360 – First steps (EN)